    Apologies in advance as I am sure this will have been discussed at some point but I'm wondering why Bulleid's pacifics all had their boiler pressure reduced from 280 psi to 250 psi during the 1950s. Was this purely to save on coal consumption or did it help to reduce wheelslip problems? As an aside, the Bulleids I am familiar with in preservation have all been downrated again to 225psi. Is this common across all preserved examples? If so was there some kind of engineering council that agreed to standardise on a lower figure or does this come from the railway inspectorate? Thanks!
     
  2. chessie1

    chessie1 New Member

    Joined:
    Aug 17, 2009
    Messages:
    197
    Likes Received:
    103
    Gender:
    Male
    Occupation:
    Retired
    Location:
    Hants
    The Bulleids that have been on the MHR over the years, and indeed those visiting examples that I've driven have all been rated at 250psi.
     
  3. Spamcan81

    Spamcan81 Nat Pres stalwart

    Joined:
    Aug 25, 2007
    Messages:
    35,121
    Likes Received:
    20,773
    Occupation:
    Training moles
    Location:
    The back of beyond
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    34081 is set to 250 psi. The reduction from 280 psi in BR service was afaik to save on boiler maintenance costs.
     
    Hampshire Unit likes this.
  4. LMS2968

    LMS2968 Part of the furniture

    Joined:
    Sep 1, 2006
    Messages:
    2,987
    Likes Received:
    5,084
    Gender:
    Male
    Occupation:
    Lecturer retired: Archivist of Stanier Mogul Fund
    Location:
    Wigan
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    For various reasons, usually to do with the steam reverser's tendency to make its own decision as to what the cut-off should be, drivers drove on the regulator and rarely, if ever opened it fully to give 280 p.s.i. at the steam chest. The high pressure therefore wasn't used but did react on maintenance costs, so was reduced to 250 p.s.i. to bring these down, without making any significant difference to the steam chest pressure.
     
  5. domeyhead

    domeyhead Member

    Joined:
    May 16, 2007
    Messages:
    396
    Likes Received:
    161
    Interesting reply from Chessie. I fired Bodmin many times for my sins back in the 80s and the pressure gauge was clearly marked to blow at 225psi which kept us firemen on our toes that little bit extra. . I wonder if Andy Netherwood looks at these pages? He will know the history if this has changed back up to 250.
     
  6. chessie1

    chessie1 New Member

    Joined:
    Aug 17, 2009
    Messages:
    197
    Likes Received:
    103
    Gender:
    Male
    Occupation:
    Retired
    Location:
    Hants
    I'm sorry to disagree but Bodmin was 250psi. The St5 was 225psi but as I say the Bulleids, 07, 16 and 105 were 250psi. I'll leave it there now.
     
  7. Steve

    Steve Resident of Nat Pres Friend

    Joined:
    Oct 7, 2006
    Messages:
    11,930
    Likes Received:
    10,088
    Occupation:
    Gentleman of leisure, nowadays
    Location:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    An S15 red-lined at 225 psi? Interesting. I thought they were either 180 or 200 psi.

    Seems I can't read......:(
     
    Last edited: Oct 24, 2017
  8. Martin Perry

    Martin Perry Nat Pres stalwart Staff Member Moderator Friend

    Joined:
    Apr 15, 2006
    Messages:
    16,510
    Likes Received:
    7,753
    Location:
    1012 / 60158
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Doesn't say that :)
     
  9. gricerdon

    gricerdon Guest

    Standard 5. Yes 250 lb saved on maintenance and has been said only rarely was more than 200 lb used then or now as you will know if you read my column. Wayne used all the steam he had climbing Honiton with Clan Line on 23rd September but that was because the coal used mean a short spell with pressure down to 180 lb until Steve Rodenhurst got it back to nearly 250 lb. On my footplate rides in the 1960s some of the drivers used all the steam available when chasing high speed, eg Dave Parsons on 34026 in January 1966 on the 530 pm down with 410 tons, recovering from a 19 mph tsr at Steventon to reach 95 mph at Winchester Jct he used 210 lb of the 210 available ie full regulator (with 22% cut off) Gordon Porter of course only ever used full regulator and expected the fireman to keep up! Poor old Tommy Moult! Oh dear nostalgia again but those were the days.
     
    Black Jim likes this.
  10. Steve

    Steve Resident of Nat Pres Friend

    Joined:
    Oct 7, 2006
    Messages:
    11,930
    Likes Received:
    10,088
    Occupation:
    Gentleman of leisure, nowadays
    Location:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    And I was even wearing my glasses when I read it! And I've just been to Specsavers.
     
    gwalkeriow likes this.
  11. 8126

    8126 Member

    Joined:
    Mar 17, 2014
    Messages:
    823
    Likes Received:
    962
    Gender:
    Male
    I don't have it to hand at this instant, but D.W. Winkworth's book on the Bulleid Pacifics states that the de-rating allowed BR to use a cheaper grade of steel for the stays, replacing one which was hard to obtain, rather than being due to any particular issues with the boilers at the higher pressure. Never seen it claimed anywhere else, but that doesn't mean there isn't some truth to it.
     
  12. martin1656

    martin1656 Nat Pres stalwart Friend

    Joined:
    Dec 8, 2014
    Messages:
    17,609
    Likes Received:
    11,223
    Gender:
    Male
    Location:
    St Leonards
    Heritage Railway Volunteer:
    No I do not currently volunteer
    An S15 pressed to 225 :eek: ok yes i know it did say Std5 :) actually 506 did run with the line set at 200 when it had the ex 825 boiler i'm not sure if when it recieved the urie boiler the pressure was dropped back to 180 or not.
     
  13. gricerdon

    gricerdon Guest

    Actually 220 lb available. This was a very good figure and showed very little loss of steam from boiler to steam chest
     
  14. RLinkinS

    RLinkinS Member

    Joined:
    Nov 8, 2008
    Messages:
    912
    Likes Received:
    928
    Gender:
    Male
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    This semms to be very plausible. Pressure vessel design codes permit lower design stresses as temperatures are increased. The saturation temperature at 280 psi is of course higher than at 250 psi so lowering the pressure wouldcould well have increased the maximum allowable stress. Of course lowering the pressure also reduced the actual stress.
     
  15. Jamessquared

    Jamessquared Nat Pres stalwart

    Joined:
    Mar 8, 2008
    Messages:
    26,103
    Likes Received:
    57,432
    Location:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    The three that I've fired (21c123 / 34028 / 34059) were all rated at 250psi.

    My understanding, as others have said, was that the reduction in boiler pressure was to save maintenance costs while having in practical (rather than theoretical) terms a fairly negligible impact on performance.

    It would be interesting to know whether a further reduction to 225psi would prolong firebox life; if so, it may well be worth doing for those running on preserved lines.

    Tom
     
  16. 8126

    8126 Member

    Joined:
    Mar 17, 2014
    Messages:
    823
    Likes Received:
    962
    Gender:
    Male
    On further reflection, my guess is that if there is anything in the stays story then the background is standardisation. The ideal for the railway is surely to keep stock of no more than one grade of copper, one grade of steel and one grade of Monel for stays. Having to keep a special grade of more expensive, possibly difficult to obtain steel on hand for two classes, even if there were a good number of them, is undesirable. If they have more than ample power, a little de-rating is tolerable.

    The maintenance costs angle is interesting, because I'm sure @Jamessquared has previously quoted costs from the mid '50s showing that the West Countries, despite high overall maintenance costs, had some of the lowest boiler repair costs across a variety of classes (like Halls, for instance). Now of course they were all still fairly new at that point, but the de-rating only started around 1952 and was not applied to all engines immediately, I think, so a lot of the data would have been when they were running around at 280psi. Chapelon's argument was always that higher boiler pressure was not necessarily a significant factor in boiler repair costs, provided good water treatment was used. Because of the steel boxes, the Bulleids needed and got good water treatment; I've occasionally wondered if some of the issues experienced in preservation are precisely due to the lack of this in the early days on preserved lines.

    I suspect it's something that just has to be accepted that Bulleids need new inner fireboxes more often than engines with copper boxes, but just think of the difference in cost for a comparable size firebox in copper. At least with the SDR all tooled up they can be done on a batch basis.
     
    Jamessquared and Bluenosejohn like this.
  17. Steve

    Steve Resident of Nat Pres Friend

    Joined:
    Oct 7, 2006
    Messages:
    11,930
    Likes Received:
    10,088
    Occupation:
    Gentleman of leisure, nowadays
    Location:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Steam loco boilers weren't built to design codes. They were designed to what the drawing office thought was OK from many years of experience.
     
    Bluenosejohn likes this.
  18. domeyhead

    domeyhead Member

    Joined:
    May 16, 2007
    Messages:
    396
    Likes Received:
    161
    When I worked on 34016 Bodmin (a JB engine) it was redlined on the gauge at 225psi and in similar fashion JB's three Maunsell moguls were downrated from their BR pressure of 225 down to 200. This was during the early 1980s and it may have been a condition of the boiler inspector back then or it may have been JB's own policy, but with the shorter train lengths on preserved lines it did not impact performance. It has occurred to me however that keeping sufficient steam without lifting the safety valves waiting at at stations is more difficult when the valve lifts at 225 rather than 250 and it needs more skill and timing from the fireman. Perhaps uprating again to 250 gives more leeway for a less experienced fireman to keep the engine from blowing off. Although to us this is merely an embarrassment and a waste of coal it does also scare the young customers , especially if the engine has a face on it at the time! :)
     
    Last edited: Oct 25, 2017
  19. Martin Perry

    Martin Perry Nat Pres stalwart Staff Member Moderator Friend

    Joined:
    Apr 15, 2006
    Messages:
    16,510
    Likes Received:
    7,753
    Location:
    1012 / 60158
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    They were expected to meet the design requirements of the insurers.
     
  20. Jamessquared

    Jamessquared Nat Pres stalwart

    Joined:
    Mar 8, 2008
    Messages:
    26,103
    Likes Received:
    57,432
    Location:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Slightly confused by that - AFAIK the Maunsell moguls were always 200psi from building.