If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

Locomotive tender classification

Discussie in 'Steam Traction' gestart door hussar1028, 21 jun 2013.

  1. hussar1028

    hussar1028 New Member

    Lid geworden:
    14 mei 2013
    Berichten:
    75
    Leuk Bevonden:
    17
    Geslacht:
    Man
    While most enthusiasts are familiar with different locomotive tenders being identified by the designer and water capacity(for example Collett 4000 gallon or Maunsell 3500 gallon) how did railway staff prior to 1968 identify them?

    Was there any difference in terminology used by footplate staff, shed fitters and works staff?

    Justin
     
  2. david1984

    david1984 Resident of Nat Pres

    Lid geworden:
    13 sep 2005
    Berichten:
    12.910
    Leuk Bevonden:
    1.387
    Geslacht:
    Man
    Locatie:
    Birmingham
    The BR Standards had a class system of sorts for various tender types (1B, 1G etc).
     
  3. GWR4707

    GWR4707 Nat Pres stalwart

    Lid geworden:
    12 mei 2006
    Berichten:
    19.232
    Leuk Bevonden:
    17.566
    Geslacht:
    Man
    Locatie:
    Cumbria
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Whilst I can understand certain variations, for loco's running backwards a lot for instance, there do seem to be a lot of variations of the 'standard' tender?
     
  4. david1984

    david1984 Resident of Nat Pres

    Lid geworden:
    13 sep 2005
    Berichten:
    12.910
    Leuk Bevonden:
    1.387
    Geslacht:
    Man
    Locatie:
    Birmingham
    Problem with tenders (particularly with Standards that could in theory be transferred anywhere) is there isn't a one size fits all solution, for example, the Southern as well documented, had no water troughs, so the largest capacity tender was favoured for loco's here when possible, additionally I believe Schools usually worked through Lymington trains as nothing larger would fit Brockenhurst Turntable, on the Standards anyway, inset coal bunkers were favoured where possible to aid rearward vision, course the most famous example being corridor tender required for non stop London - Scotland.

    Would I be right in guessing it was a similar reason to the Schools on Lymingtons why B12's had such tiny tenders ?.
     
  5. buseng

    buseng Part of the furniture

    Lid geworden:
    9 sep 2005
    Berichten:
    4.801
    Leuk Bevonden:
    349
    Geslacht:
    Man
    Beroep:
    Retired
    Locatie:
    Tilehurst, Reading, Berks.
    Don't forget from around 1961 some Schools received the large bogie tenders from withdrawn Lord Nelsons. The tender was nearly as big as the loco!


    http://www.semgonline.com/steam/pics/mm_30912-1.jpg
     
  6. 22A

    22A Well-Known Member

    Lid geworden:
    8 sep 2005
    Berichten:
    1.105
    Leuk Bevonden:
    99
    Beroep:
    Administrator
    Locatie:
    Between 31F & 34E
    The Bulleid used for the 1948 exchanges was paired with a tender from a Stanier 8F.
    As fir the BR Standard tenders; Duke of Gloucester is paired with the tender from a 9F, but it looks right.
    It was a frequent occurrence for locos going into Swindon for overhaul would emerge with a completely different tender.
     
  7. marshall5

    marshall5 Part of the furniture

    Lid geworden:
    26 okt 2010
    Berichten:
    2.522
    Leuk Bevonden:
    4.361
    Locatie:
    i.o.m
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Wasn't the Duke's original tender the only BR Std tender with a coal pusher? IIRC it went to Briton Ferry steelworks for use as an ingot carrier. Ray.
     
  8. oddsocks

    oddsocks Well-Known Member

    Lid geworden:
    22 nov 2009
    Berichten:
    1.813
    Leuk Bevonden:
    289
    Geslacht:
    Man
    Beroep:
    Retired / Dodging a Coffin for as long as I can.
    Locatie:
    Half a mile east of Snells Nook Halt. (1883-1931)
    Heritage Railway Volunteer:
    No I do not currently volunteer
    The final batch of ten Britannias had BR1D tenders, these had coal pushers fitted.
     
  9. david1984

    david1984 Resident of Nat Pres

    Lid geworden:
    13 sep 2005
    Berichten:
    12.910
    Leuk Bevonden:
    1.387
    Geslacht:
    Man
    Locatie:
    Birmingham
    I meant to ask about that, I presume it was to make use of other regions troughs, as all LNER, LMS & GWR Loco's in the trials retained their standard tenders.
     
  10. williamfj2

    williamfj2 Member

    Lid geworden:
    21 dec 2007
    Berichten:
    637
    Leuk Bevonden:
    56
    Geslacht:
    Man
    Locatie:
    50A
    If memory serves the LMS locos used on Southern metals ran with Dub Dee tenders.
     

Deel Deze Pagina