If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

Tornado

Rasprava u 'Steam Traction' pokrenuta od Leander's Shovel, 20. Listopad 2007..

  1. 60017

    60017 Resident of Nat Pres Friend

    Pridružen(a):
    6. Srpanj 2008.
    Poruka:
    9,103
    Lajkova:
    8,072
    Spol:
    Muškarac
    Interesi:
    Retired from corporate slavery :o)
    Grad:
    Fylde Coast
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Good news indeed. I will also be pleased to see the A1 back on the mainline. Welcome back young'un!
     
  2. Dan Hill

    Dan Hill Part of the furniture

    Pridružen(a):
    1. Kolovoz 2008.
    Poruka:
    2,751
    Lajkova:
    831
    Spol:
    Muškarac
    Interesi:
    Brick Machine Operator
    Grad:
    Haywards Heath
    Heritage Railway Volunteer:
    No I do not currently volunteer
    On the subject of young it feels strange with me being a 19 nearly 20 year old but being older than a steam locomotive.
     
  3. Dan Hamblin

    Dan Hamblin Part of the furniture

    Pridružen(a):
    27. Ožujak 2006.
    Poruka:
    2,549
    Lajkova:
    190
    Interesi:
    Rolling Stock Engineer
    Grad:
    Kent
    I went to a presentation tonight given by a gentleman from the ORR on Rolling Stock Approval, Verification and Assurance where he raised a rather interesting fact. Tornado is actually approved as interoperable under the European Interoperability Regulations.

    Regards,

    Dan
     
  4. 34007

    34007 Part of the furniture

    Pridružen(a):
    16. Ožujak 2007.
    Poruka:
    3,166
    Lajkova:
    2
    Spol:
    Muškarac
    Grad:
    Hampshire
    So does that mean the loco is fit to run elsewhere where she is in gauge? i.e other countries?
     
  5. Dan Hamblin

    Dan Hamblin Part of the furniture

    Pridružen(a):
    27. Ožujak 2006.
    Poruka:
    2,549
    Lajkova:
    190
    Interesi:
    Rolling Stock Engineer
    Grad:
    Kent
    In short, yes! Obviously it would have to be compatible with the signalling etc. and there would be operability issues surrounding coupling and braking etc. but from a technical compliance viewpoint it can go anywhere in Europe that has implemented the Interoperability Regs.

    Regards,

    Dan
     
  6. keith6233

    keith6233 Member

    Pridružen(a):
    21. Travanj 2006.
    Poruka:
    601
    Lajkova:
    184
    Interesi:
    Engineer
    Grad:
    Manchester
    One of the important reasons that it could operate in Europe is it carries a CE mark on the boiler .
     
  7. williamfj2

    williamfj2 Member

    Pridružen(a):
    21. Prosinac 2007.
    Poruka:
    637
    Lajkova:
    56
    Spol:
    Muškarac
    Grad:
    50A
    Did 5521 carry the CE mark or did it have grandfather rights when it was running in Poland then?
     
  8. Fred Kerr

    Fred Kerr Resident of Nat Pres Friend

    Pridružen(a):
    24. Ožujak 2006.
    Poruka:
    8,383
    Lajkova:
    5,368
    Spol:
    Muškarac
    Interesi:
    Freelance photo - journalist
    Grad:
    Southport
    Nope - it was certified IIRC as an Hungarian locomotive and therefore gained rights to European networks ( including Poland ) under that nomenclature.
     
  9. Eightpot

    Eightpot Resident of Nat Pres Friend

    Pridružen(a):
    10. Kolovoz 2006.
    Poruka:
    8,340
    Lajkova:
    2,506
    Spol:
    Muškarac
    Interesi:
    Engineer Emeritus
    Grad:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    A bit difficult to see from the photos, but I gain the impression that a lot of flexible stays have now been installed over the top of the combustion chamber and front part of the firebox crown compared with previous photos prior to the boiler's departure to Meiningen.
     
  10. Guest

    Guest Part of the furniture Account Suspended

    Pridružen(a):
    8. Rujan 2005.
    Poruka:
    3,614
    Lajkova:
    21
    Interesi:
    Occasional
    Grad:
    G C & N S
    Richard - you may be right.

    I don't know how you fit "longer" stays to an inner and outer of constant dimensions, but Graham was at pains on Friday to say that the longer the stay the more tolerant to cracking it would be.
     
  11. Argus

    Argus New Member

    Pridružen(a):
    14. Srpanj 2010.
    Poruka:
    75
    Lajkova:
    30
    Spol:
    Muškarac
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    At least the boiler has something going for it then!!!
     
  12. irwellsteam

    irwellsteam Member

    Pridružen(a):
    5. Siječanj 2011.
    Poruka:
    796
    Lajkova:
    176
    Interesi:
    -
    Grad:
    -
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Here we go again............. :(
     
  13. Steve

    Steve Resident of Nat Pres Friend

    Pridružen(a):
    7. Listopad 2006.
    Poruka:
    12,730
    Lajkova:
    11,847
    Interesi:
    Gentleman of leisure, nowadays
    Grad:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    As you say, a bit difficult to tell from published photos but I reckon that there has been no change to the combustion chamber and side sheets. Not sure about the back plate but it would be unusual to fit flexibles there
    Definitely right to say that the longer the stay, the better. As I've said before, IMHO, stay length is the main problem. With welded stays, for a given water space, you can maximise it by having clearance holes and fillet welds, rather than J prep and tight holes. I don't know if that's what they've done, though. They've replaced quite a bit of platework so it's just possible that water spaces have been slightly increased. That's a bit of serious modding, though!
     
  14. keith6233

    keith6233 Member

    Pridružen(a):
    21. Travanj 2006.
    Poruka:
    601
    Lajkova:
    184
    Interesi:
    Engineer
    Grad:
    Manchester
    Definitely right to say that the longer the stay, the better. As I've said before, IMHO, stay length is the main problem. With welded stays, for a given water space, you can maximise it by having clearance holes and fillet welds, rather than J prep and tight holes. I don't know if that's what they've done, though. They've replaced quite a bit of platework so it's just possible that water spaces have been slightly increased. That's a bit of serious modding, though![/QUOTE]

    Speaking to one of the A1 team at the weekend the stays now protrude through and are fillet welded .originally they were flush with the side sheet also they are tube blanked of at one end instead of drilled bar.

    Remember it's a learning curve for everybody.
     
  15. S.A.C. Martin

    S.A.C. Martin Part of the furniture

    Pridružen(a):
    31. Kolovoz 2010.
    Poruka:
    5,615
    Lajkova:
    9,418
    Spol:
    Muškarac
    Interesi:
    Asset Engineer (Signalling), MNLPS Treasurer
    Grad:
    London
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Treat it with the contempt it deserves, chap.

    I am intrigued at the discussion of stay length. Why is it exactly that a longer stay resists cracking better?
     
  16. Eightpot

    Eightpot Resident of Nat Pres Friend

    Pridružen(a):
    10. Kolovoz 2006.
    Poruka:
    8,340
    Lajkova:
    2,506
    Spol:
    Muškarac
    Interesi:
    Engineer Emeritus
    Grad:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    For a given movement of the inner firebox relative to the outer wrapper (as an example), the longer the stay can be between the two results in a lesser bending angle of the stay.

    Just hope that I've expressed it clearly enough!
     
  17. bongo jim

    bongo jim New Member

    Pridružen(a):
    17. Kolovoz 2009.
    Poruka:
    32
    Lajkova:
    1
    Speaking to one of the A1 team at the weekend the stays now protrude through and are fillet welded .originally they were flush with the side sheet also they are tube blanked of at one end instead of drilled bar.

    Remember it's a learning curve for everybody.[/QUOTE]

    Not sure where this came from, but when I looked in tornado's firebox a while back it had stays that protrude through and were fillet welded as per normal German/American/Chinese practice to name a few.
    Seems very strange [and costly] to have stays that are made of tube and blanked one end?
     
  18. S.A.C. Martin

    S.A.C. Martin Part of the furniture

    Pridružen(a):
    31. Kolovoz 2010.
    Poruka:
    5,615
    Lajkova:
    9,418
    Spol:
    Muškarac
    Interesi:
    Asset Engineer (Signalling), MNLPS Treasurer
    Grad:
    London
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Thank you - so a shorter stay will always result in a greater bending angle? For example, ff both a stay of X length is compared to a stay of length 2X, will the bending angle be larger in proportion to its length if the same factors (heat/pressure) are applied to both stays?
     
  19. Steve

    Steve Resident of Nat Pres Friend

    Pridružen(a):
    7. Listopad 2006.
    Poruka:
    12,730
    Lajkova:
    11,847
    Interesi:
    Gentleman of leisure, nowadays
    Grad:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    O level geometry. Draw it out and make your own conclusion.
    O level? Showing my age, again!
     
  20. Eightpot

    Eightpot Resident of Nat Pres Friend

    Pridružen(a):
    10. Kolovoz 2006.
    Poruka:
    8,340
    Lajkova:
    2,506
    Spol:
    Muškarac
    Interesi:
    Engineer Emeritus
    Grad:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Yes, but also factor in the same amount of movement of both inner and outer firebox plates relative to one another. The solution of the right-angled triangle will demonstrate this.
     

Podijelite ovu stranicu