If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

D9009 Alycidon

الموضوع في 'Diesel & Electric Traction' بواسطة neildimmer, بتاريخ ‏6 إبريل 2013.

  1. D1002

    D1002 Resident of Nat Pres

    إنضم إلينا في:
    ‏25 إبريل 2011
    المشاركات:
    9,847
    عدد المعجبين:
    7,548
    الجنس:
    ذكر
    مكان الإقامة:
    Enfield
    The Capital Deltic Reprise, 55009 Alycidon, 29th July 2023.
    Filmed at Woolmer Green Junction and Welham Green:



    Hard to believe I photographed 55016 Gordon Highlander at the same location as the first clip 50 years ago:

    IMG_0322.png
     
    Last edited: ‏30 جويلية 2023
    أعجب بهذه المشاركة nige757
  2. Sidmouth

    Sidmouth Resident of Nat Pres Staff Member Moderator

    إنضم إلينا في:
    ‏12 سبتمبر 2005
    المشاركات:
    10,146
    عدد المعجبين:
    9,777
    الجنس:
    ذكر
    مكان الإقامة:
    Alderan !
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    out of interest and appreciating that Deltics do throw oil anyway , but is there a cause of the obvious oil leak down the side of 55009 which seems more than normal
     
  3. Swiss Toni

    Swiss Toni Well-Known Member

    إنضم إلينا في:
    ‏9 نوفمبر 2008
    المشاركات:
    1,961
    عدد المعجبين:
    3,664
    مكان الإقامة:
    Switzshire
    Victor, misspentyouth62, green five و 5 آخرون معجبون بهذا.
  4. Victor

    Victor Nat Pres stalwart Friend

    إنضم إلينا في:
    ‏20 أوت 2006
    المشاركات:
    14,526
    عدد المعجبين:
    9,197
    الوظيفة:
    Retired
    مكان الإقامة:
    DEWSBURY West Yorkshire
    For a railway enthusiast (like wot I am) there's not a much better sight and sound than a Deltic locomotive in good nick and going well.
    Thanks to all for the photos and video clips.
     
    Last edited: ‏30 جويلية 2023
    أعجب بهذه المشاركة osprey
  5. guycarr360

    guycarr360 Part of the furniture

    إنضم إلينا في:
    ‏4 اكتوبر 2005
    المشاركات:
    4,834
    عدد المعجبين:
    3,157
    الجنس:
    ذكر
    مكان الإقامة:
    Chester le Street County Durham
    Shunting before start of tour being blamed for oil usage and exit, a better explanation can be given if required.

    " basically because the engines never have chance to rev and get under load properly so they are just almost idling. As the oil pumps are gear driven and therefore linked directly to engine speed this allows oil to settle in the galleries and journals. Also the engine won't get up to temperature properly so when a sudden demand of power is applied this oil will be forced past the piston rings that haven't properly expanded yet and henceforth oil sprayed out the exhaust."
     
  6. osprey

    osprey Resident of Nat Pres

    إنضم إلينا في:
    ‏3 اكتوبر 2007
    المشاركات:
    10,494
    عدد المعجبين:
    2,853
    الوظيفة:
    semi-retired, currently doing R&D for my patents
    مكان الإقامة:
    Halifax
    I've never studied the Deltic engine deeply, but realise it is a two stroke engine having exhaust ports not exhaust valves. Surely there must some lubrication oil passing out to atmosphere via the ports?
     
  7. Eightpot

    Eightpot Resident of Nat Pres Friend

    إنضم إلينا في:
    ‏10 أوت 2006
    المشاركات:
    8,340
    عدد المعجبين:
    2,506
    الجنس:
    ذكر
    الوظيفة:
    Engineer Emeritus
    مكان الإقامة:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    When a Deltic arrived at the Kings Cross servicing depot, having come from Edinburgh, it was quite normal to have to add five gallons of engine lubricating oil to each engine.
     
    أعجب بهذه المشاركة DavidW
  8. osprey

    osprey Resident of Nat Pres

    إنضم إلينا في:
    ‏3 اكتوبر 2007
    المشاركات:
    10,494
    عدد المعجبين:
    2,853
    الوظيفة:
    semi-retired, currently doing R&D for my patents
    مكان الإقامة:
    Halifax
    Well
    Wonder where it went?
     
  9. guycarr360

    guycarr360 Part of the furniture

    إنضم إلينا في:
    ‏4 اكتوبر 2005
    المشاركات:
    4,834
    عدد المعجبين:
    3,157
    الجنس:
    ذكر
    مكان الإقامة:
    Chester le Street County Durham
    Power Unit 451, split pin broke, and allowed a nut/bolt to come, loose, only repair possible meant lying on top of a red hot engine, so wasnt repaired.
    Power Unit 408 is de-rated due to number of hours.
     
    أعجب بهذه المشاركة Sidmouth
  10. guycarr360

    guycarr360 Part of the furniture

    إنضم إلينا في:
    ‏4 اكتوبر 2005
    المشاركات:
    4,834
    عدد المعجبين:
    3,157
    الجنس:
    ذكر
    مكان الإقامة:
    Chester le Street County Durham
    Depot Report - Saturday 5th August 2023
    55009
    Busy day carrying out the 8 points on 55009 from Thursdays Audit. 6 completed and 1 to do, OTMR removed by Dave and to be repaired or replaced with spare.
    No 2 cab Reverser not switching over and could not take power, Bill took the cover off and dry cleaned before cleaning contactor strips. Steve W did the same at the other end. Both now working correctly. Pete checked the load Regulator in No 2 cubicle, after Bill had cleaned it, again Steve did the other end, Pete checked it over then made a slight adjustment and now sits back to zero.
    William checked and closed a slight oil leak and a coolant leak, no leaks shown on running up tests.
    Richie spent some time checking around the prop shafts on the cooling modules especially the top shaft on no 2 to the secondary gear box. The loco has a full set of refurbished & balanced shafts with new UJ Joints and seals
    The loco was run up and all systems worked as they should, just need the OTMR and all is good to go.
     
    DavidW, Woolley و cymroglan معجبون بهذا.
  11. guycarr360

    guycarr360 Part of the furniture

    إنضم إلينا في:
    ‏4 اكتوبر 2005
    المشاركات:
    4,834
    عدد المعجبين:
    3,157
    الجنس:
    ذكر
    مكان الإقامة:
    Chester le Street County Durham
  12. Victor

    Victor Nat Pres stalwart Friend

    إنضم إلينا في:
    ‏20 أوت 2006
    المشاركات:
    14,526
    عدد المعجبين:
    9,197
    الوظيفة:
    Retired
    مكان الإقامة:
    DEWSBURY West Yorkshire
    Bad news, The DPS report that power unit 451 in Alycidon has suffered (their words) 'a complete failure':Banghead: The cause is not known at this time, BUGGA.:(
     
  13. guycarr360

    guycarr360 Part of the furniture

    إنضم إلينا في:
    ‏4 اكتوبر 2005
    المشاركات:
    4,834
    عدد المعجبين:
    3,157
    الجنس:
    ذكر
    مكان الإقامة:
    Chester le Street County Durham
    Its the one on high hours, and was already de-rated according to reports, and the reason behind the cancellation for the NYMR visit.

    The second unit, is the same, you wonder if the time is right to look at a rebuild of one, dont know how much the units in RSG have been di-assembled.

    Hope is does not mean one of the Tulyar units becomes a donor, especially when they are so close to pressing the button.
     
    أعجب بهذه المشاركة The Green Howards
  14. The Green Howards

    The Green Howards Nat Pres stalwart

    إنضم إلينا في:
    ‏20 فبراير 2016
    المشاركات:
    15,106
    عدد المعجبين:
    8,633
    الوظيفة:
    Layabout
    مكان الإقامة:
    My settee, mostly.
    Heritage Railway Volunteer:
    No I do not currently volunteer
  15. The Green Howards

    The Green Howards Nat Pres stalwart

    إنضم إلينا في:
    ‏20 فبراير 2016
    المشاركات:
    15,106
    عدد المعجبين:
    8,633
    الوظيفة:
    Layabout
    مكان الإقامة:
    My settee, mostly.
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Further information on the failure of p/u 451:

    https://www.thedps.co.uk/post/depot-report-saturday-1st-june-2024
     
    أعجب بهذه المشاركة DavidW
  16. guycarr360

    guycarr360 Part of the furniture

    إنضم إلينا في:
    ‏4 اكتوبر 2005
    المشاركات:
    4,834
    عدد المعجبين:
    3,157
    الجنس:
    ذكر
    مكان الإقامة:
    Chester le Street County Durham
    Was thinking about this last night, and with the phasing case looking to be the culprit, and with the opposed piston operation, i think the main block may be OK.
    Obviously the phasing assembly has an issue, but in normal operation, the pistons dont get near each other anyway, and the crankshaft stops them over reaching to cause piston to piston contact.
    However, wish them all of the best with re-activating pu 430, and will donate to the generator repairs.
     
  17. guycarr360

    guycarr360 Part of the furniture

    إنضم إلينا في:
    ‏4 اكتوبر 2005
    المشاركات:
    4,834
    عدد المعجبين:
    3,157
    الجنس:
    ذكر
    مكان الإقامة:
    Chester le Street County Durham
    On its way back to Barrow Hill, photo courtesy of Jake Thomas
    448203890_895073895965653_100766474730454631_n.jpg
     
    DavidW و Victor معجبون بهذا.

مشاركة هذه الصفحة