    Obviously in a Diesel you can fill the radiators with anti-freeze but how do you protect a steam loco in sub zero temperatures - I have seen the gauge glasses on a laid up ship burst in sub zero temperatures.

    Following on from that how are active locos treated when they are 'laid up' over winter? Are the boilers and tenders drained?
     
  2. flying scotsman123

    flying scotsman123 Resident of Nat Pres

    注册日期:
    2013-09-09
    帖子:
    10,674
    支持:
    18,699
    性别:
    所在地:
    Cheltenham
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Certainly steam locos are "winterised" - all water drained from boiler and tender. What is done more short term I don't know.
     
  3. Martin Perry

    Martin Perry Nat Pres stalwart Staff Member Moderator Friend

    注册日期:
    2006-04-15
    帖子:
    16,551
    支持:
    7,897
    所在地:
    1012 / 60158
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Not all diesels reacted well to use of anti-freeze. This may have been down to BR using cheap after market liner seals in the past, but BR frost precautions for many years seemed to be to let everything run on tick over constantly. Bet the neighbours loved it.
     
  4. Steve

    Steve Resident of Nat Pres Friend

    注册日期:
    2006-10-07
    帖子:
    12,729
    支持:
    11,847
    职业:
    Gentleman of leisure, nowadays
    所在地:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Probably more important is getting all the water out of the pipes and fittings. Burst injectors aren't cheap to replace. Keeping service locos indoors helps a bit but only if the building is well insulated. Other things done include wrapping all vulnerable bits in a thick layer of rags. Watch out for ice in cylinders if moving a dead loco as ice is just as incompressible as water and won't come out via the drain cocks.
    Running steam in winter is such fun!
     
    已获得jtx, LMS2968, Wenlock另外1人的支持.
  5. Ploughman

    Ploughman Part of the furniture

    注册日期:
    2008-04-01
    帖子:
    5,969
    支持:
    2,761
    职业:
    Ex a lot of things.
    所在地:
    Near where the 3 Ridings meet
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    You could always light a fire in a steam engine.

    One other problem area is for those involved in PW works.
    Concrete sleepers sticking to each other when being lifted.
    Ballast frozen in the hoppers.
    Chairs breaking when trying to key up.
    Cant find the railway due to it being buried in 4ft of snow, although I might have an answer for that one.
    All experienced in the last 6 years on the NYMR
     
    已获得4468BenV, Sheff, CH 19另外1人的支持.
  6. Steve

    Steve Resident of Nat Pres Friend

    注册日期:
    2006-10-07
    帖子:
    12,729
    支持:
    11,847
    职业:
    Gentleman of leisure, nowadays
    所在地:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Not necessarily true if it is frozen.
    Steam heated coaches can be fun, too.. Introducing steam into a frozen up pipe will not clear it as there is no flow.
     
  7. martin1656

    martin1656 Nat Pres stalwart Friend

    注册日期:
    2014-12-08
    帖子:
    19,263
    支持:
    12,515
    性别:
    所在地:
    St Leonards
    Heritage Railway Volunteer:
    No I do not currently volunteer
    in some cases injector cones are removed, and pipes covered to prevent build up of ice, and in the case of locos needed to be in service we used to light braziers next to the engines a few days before to keep the temperature above freezing and light warming fires in the loco over a 24hour period before lighting up
     
    已获得flying scotsman123的支持.
  8. olly5764

    olly5764 Well-Known Member

    注册日期:
    2006-12-29
    帖子:
    1,887
    支持:
    1,017
    性别:
    职业:
    Engineer
    所在地:
    Normally in a brake van somewhere
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Wrap the injectors and lubricator up, fill the lubricator with oil, open the injector foot valves (if it has them) open the steam heat cocks
     
  9. jtx

    jtx Well-Known Member

    注册日期:
    2007-07-04
    帖子:
    1,868
    支持:
    855
    性别:
    职业:
    Happily retired
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    One of the easiest ways to prevent problems, if you have people willing and able to do it, is just to maintain a small fire in the firebox. A dozen shovels, (in a big engine), will cook nicely, with doors and damper shut, for hours. Experience will tell how long. Returning to the engine, with one or two red embers left, a lump of wood and the back damper open for short time, will re-ignite the fire, then you can top up again, with a dozen, or more shovels, and if you can find some slack in the tender, pack it on top.

    You are not looking to make steam, just keeping the water tepid. A boiler with a small fire in, will not freeze, neither will any ancillary kit, like sight feed lubricators / gauge glasses, becuase they are bolted to the boiler backhead, which will remain slightly warm.

    It is surprising just how little heat is required to stop somewhere freezing. In the grim fifties, our outside toilet was kept frost - free by a small oil lamp, little more than a candle in a glass. It smelt a bit of paraffin, but it didn't freeze.
     
  10. Steve

    Steve Resident of Nat Pres Friend

    注册日期:
    2006-10-07
    帖子:
    12,729
    支持:
    11,847
    职业:
    Gentleman of leisure, nowadays
    所在地:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    That's what I tend to do if a loco has to stand outside. Still need to be wary of low positioned injectors and pipework if it gets really cold, especially if there is no steam to leak through valves. A problem I've found with small locos is that if you don't raise steam to get the blower on, the tubes can soon block up, creating a different problem.
    I often wonder how they coped in Scandinavia and similar countries.
     
  11. Sheff

    Sheff Resident of Nat Pres

    注册日期:
    2006-04-21
    帖子:
    8,057
    支持:
    3,137
    性别:
    职业:
    Retired Engineer & Heritage Volunteer
    所在地:
    N Warks
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    It's interesting to note the differences in loco's imported from colder climes - eg some S160's and the WD at the KWVR.

    e.g In the case of the Chinese S160's they are fitted with lifting injectors so no low-level pipework full of cold water to freeze up.
     
  12. AndyY

    AndyY Member

    注册日期:
    2013-02-23
    帖子:
    433
    支持:
    480
    I believe some of the loco on the Swiss narrow gauge railways are fitted with an electric immersion heater in the boiler to keep the water warm without a fire.
     
  13. huochemi

    huochemi Part of the furniture

    注册日期:
    2008-05-06
    帖子:
    2,995
    支持:
    1,515
    性别:
    所在地:
    UK
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I suspect the S160s/KD6 in China lost their original Nathans to mainline locos (and their DV4 lubricators). QJs originally had a lifting injector on the fireman's side but these all seem to have been replaced in later years or fitted ab initio to new builds relatively early on.
     
    已获得Sheff的支持.
  14. Romsey

    Romsey Part of the furniture

    注册日期:
    2007-07-14
    帖子:
    3,868
    支持:
    1,849
    性别:
    职业:
    Retired SPM
    所在地:
    Close to Spike Island
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Yes, the SLM/DLM rack locos for the Brienz Rothorn Bahn, MGN and OBB (Schafberg) built in the late 1980's were fitted with immersion heaters to keep the boilers warm overnight and reduce prep time.