If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

Tornado

本贴由 Leander's Shovel2007-10-20 发布. 版块名称: Steam Traction

  1. 60017

    60017 Resident of Nat Pres Friend

    注册日期:
    2008-07-06
    帖子:
    9,103
    支持:
    8,072
    性别:
    职业:
    Retired from corporate slavery :o)
    所在地:
    Fylde Coast
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Good news indeed. I will also be pleased to see the A1 back on the mainline. Welcome back young'un!
     
  2. Dan Hill

    Dan Hill Part of the furniture

    注册日期:
    2008-08-01
    帖子:
    2,751
    支持:
    831
    性别:
    职业:
    Brick Machine Operator
    所在地:
    Haywards Heath
    Heritage Railway Volunteer:
    No I do not currently volunteer
    On the subject of young it feels strange with me being a 19 nearly 20 year old but being older than a steam locomotive.
     
  3. Dan Hamblin

    Dan Hamblin Part of the furniture

    注册日期:
    2006-03-27
    帖子:
    2,549
    支持:
    190
    职业:
    Rolling Stock Engineer
    所在地:
    Kent
    I went to a presentation tonight given by a gentleman from the ORR on Rolling Stock Approval, Verification and Assurance where he raised a rather interesting fact. Tornado is actually approved as interoperable under the European Interoperability Regulations.

    Regards,

    Dan
     
  4. 34007

    34007 Part of the furniture

    注册日期:
    2007-03-16
    帖子:
    3,166
    支持:
    2
    性别:
    所在地:
    Hampshire
    So does that mean the loco is fit to run elsewhere where she is in gauge? i.e other countries?
     
  5. Dan Hamblin

    Dan Hamblin Part of the furniture

    注册日期:
    2006-03-27
    帖子:
    2,549
    支持:
    190
    职业:
    Rolling Stock Engineer
    所在地:
    Kent
    In short, yes! Obviously it would have to be compatible with the signalling etc. and there would be operability issues surrounding coupling and braking etc. but from a technical compliance viewpoint it can go anywhere in Europe that has implemented the Interoperability Regs.

    Regards,

    Dan
     
  6. keith6233

    keith6233 Member

    注册日期:
    2006-04-21
    帖子:
    601
    支持:
    184
    职业:
    Engineer
    所在地:
    Manchester
    One of the important reasons that it could operate in Europe is it carries a CE mark on the boiler .
     
  7. williamfj2

    williamfj2 Member

    注册日期:
    2007-12-21
    帖子:
    637
    支持:
    56
    性别:
    所在地:
    50A
    Did 5521 carry the CE mark or did it have grandfather rights when it was running in Poland then?
     
  8. Fred Kerr

    Fred Kerr Resident of Nat Pres Friend

    注册日期:
    2006-03-24
    帖子:
    8,383
    支持:
    5,368
    性别:
    职业:
    Freelance photo - journalist
    所在地:
    Southport
    Nope - it was certified IIRC as an Hungarian locomotive and therefore gained rights to European networks ( including Poland ) under that nomenclature.
     
  9. Eightpot

    Eightpot Resident of Nat Pres Friend

    注册日期:
    2006-08-10
    帖子:
    8,340
    支持:
    2,506
    性别:
    职业:
    Engineer Emeritus
    所在地:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    A bit difficult to see from the photos, but I gain the impression that a lot of flexible stays have now been installed over the top of the combustion chamber and front part of the firebox crown compared with previous photos prior to the boiler's departure to Meiningen.
     
  10. Guest

    Guest Part of the furniture Account Suspended

    注册日期:
    2005-09-08
    帖子:
    3,614
    支持:
    21
    职业:
    Occasional
    所在地:
    G C & N S
    Richard - you may be right.

    I don't know how you fit "longer" stays to an inner and outer of constant dimensions, but Graham was at pains on Friday to say that the longer the stay the more tolerant to cracking it would be.
     
  11. Argus

    Argus New Member

    注册日期:
    2010-07-14
    帖子:
    75
    支持:
    30
    性别:
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    At least the boiler has something going for it then!!!
     
  12. irwellsteam

    irwellsteam Member

    注册日期:
    2011-01-05
    帖子:
    796
    支持:
    176
    职业:
    -
    所在地:
    -
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Here we go again............. :(
     
  13. Steve

    Steve Resident of Nat Pres Friend

    注册日期:
    2006-10-07
    帖子:
    12,730
    支持:
    11,847
    职业:
    Gentleman of leisure, nowadays
    所在地:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    As you say, a bit difficult to tell from published photos but I reckon that there has been no change to the combustion chamber and side sheets. Not sure about the back plate but it would be unusual to fit flexibles there
    Definitely right to say that the longer the stay, the better. As I've said before, IMHO, stay length is the main problem. With welded stays, for a given water space, you can maximise it by having clearance holes and fillet welds, rather than J prep and tight holes. I don't know if that's what they've done, though. They've replaced quite a bit of platework so it's just possible that water spaces have been slightly increased. That's a bit of serious modding, though!
     
  14. keith6233

    keith6233 Member

    注册日期:
    2006-04-21
    帖子:
    601
    支持:
    184
    职业:
    Engineer
    所在地:
    Manchester
    Definitely right to say that the longer the stay, the better. As I've said before, IMHO, stay length is the main problem. With welded stays, for a given water space, you can maximise it by having clearance holes and fillet welds, rather than J prep and tight holes. I don't know if that's what they've done, though. They've replaced quite a bit of platework so it's just possible that water spaces have been slightly increased. That's a bit of serious modding, though![/QUOTE]

    Speaking to one of the A1 team at the weekend the stays now protrude through and are fillet welded .originally they were flush with the side sheet also they are tube blanked of at one end instead of drilled bar.

    Remember it's a learning curve for everybody.
     
  15. S.A.C. Martin

    S.A.C. Martin Part of the furniture

    注册日期:
    2010-08-31
    帖子:
    5,615
    支持:
    9,418
    性别:
    职业:
    Asset Engineer (Signalling), MNLPS Treasurer
    所在地:
    London
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Treat it with the contempt it deserves, chap.

    I am intrigued at the discussion of stay length. Why is it exactly that a longer stay resists cracking better?
     
  16. Eightpot

    Eightpot Resident of Nat Pres Friend

    注册日期:
    2006-08-10
    帖子:
    8,340
    支持:
    2,506
    性别:
    职业:
    Engineer Emeritus
    所在地:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    For a given movement of the inner firebox relative to the outer wrapper (as an example), the longer the stay can be between the two results in a lesser bending angle of the stay.

    Just hope that I've expressed it clearly enough!
     
  17. bongo jim

    bongo jim New Member

    注册日期:
    2009-08-17
    帖子:
    32
    支持:
    1
    Speaking to one of the A1 team at the weekend the stays now protrude through and are fillet welded .originally they were flush with the side sheet also they are tube blanked of at one end instead of drilled bar.

    Remember it's a learning curve for everybody.[/QUOTE]

    Not sure where this came from, but when I looked in tornado's firebox a while back it had stays that protrude through and were fillet welded as per normal German/American/Chinese practice to name a few.
    Seems very strange [and costly] to have stays that are made of tube and blanked one end?
     
  18. S.A.C. Martin

    S.A.C. Martin Part of the furniture

    注册日期:
    2010-08-31
    帖子:
    5,615
    支持:
    9,418
    性别:
    职业:
    Asset Engineer (Signalling), MNLPS Treasurer
    所在地:
    London
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Thank you - so a shorter stay will always result in a greater bending angle? For example, ff both a stay of X length is compared to a stay of length 2X, will the bending angle be larger in proportion to its length if the same factors (heat/pressure) are applied to both stays?
     
  19. Steve

    Steve Resident of Nat Pres Friend

    注册日期:
    2006-10-07
    帖子:
    12,730
    支持:
    11,847
    职业:
    Gentleman of leisure, nowadays
    所在地:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    O level geometry. Draw it out and make your own conclusion.
    O level? Showing my age, again!
     
  20. Eightpot

    Eightpot Resident of Nat Pres Friend

    注册日期:
    2006-08-10
    帖子:
    8,340
    支持:
    2,506
    性别:
    职业:
    Engineer Emeritus
    所在地:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Yes, but also factor in the same amount of movement of both inner and outer firebox plates relative to one another. The solution of the right-angled triangle will demonstrate this.
     

分享此页面