If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

Condensing apparatus on steam locomotives.

Dieses Thema im Forum 'Steam Traction' wurde von Matt35027 gestartet, 26 Januar 2013.

  1. marshall5

    marshall5 Part of the furniture

    Registriert seit:
    26 Oktober 2010
    Beiträge:
    2.560
    Zustimmungen:
    4.470
    Ort:
    i.o.m
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Tom, I don't think there was a separate tank - just the normal side tanks. Didn't the 97xx panniers also have a dump valve under the bunker with a large wheel on the fireman's side? Ray.
     
  2. guard_jamie

    guard_jamie Part of the furniture

    Registriert seit:
    7 Juli 2008
    Beiträge:
    2.503
    Zustimmungen:
    27
    Geschlecht:
    männlich
    Beruf:
    Signalman
    Ort:
    Herefordshire
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I visited the LTM the other weekend, and read there that the 4-4-0Ts had to have their tanks drained after two round trips because of the temperature rising in the tanks.
     
  3. std tank

    std tank Part of the furniture

    Registriert seit:
    20 September 2005
    Beiträge:
    3.949
    Zustimmungen:
    1.087
    Geschlecht:
    männlich
    Beruf:
    Retired
    Ort:
    Liverpool
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    The Wild Swan Midland Engines book No 5 The Johnson 2441 Class is interesting reading. This is about the 3F 0-6-0 tanks 47200-59, some of which were fitted with condensing gear.
    Both Moorgate Street and Farringdon had pit roads were the side tanks could be quickly drained of hot water and refilled.
     
  4. John Hughes

    John Hughes New Member

    Registriert seit:
    5 März 2016
    Beiträge:
    4
    Zustimmungen:
    1
    Geschlecht:
    männlich
    Ort:
    Liverpool
    Heritage Railway Volunteer:
    No I do not currently volunteer
    An engineering drawing of a Kitson tank for the Mersey Railway shows the condensing pipe running into the front of the side tank and then carrying on horizontally until it suddenly jinks up to form a semicircle outside the tank (why?) and so vertically down to near the bottom of the tank. So far as I can see there is no fancy heat exchanger – the steam is just vented into the water at the bottom of the tank. (Most of the time, the horizontal pipe would surely be above the water level.) I cannot imagine the steam being condensed very effectively unless there was quite a depth of water in the tank, so did the enginemen have to make sure the tanks were never more than half empty? Was this why they had to discard the hot water at the end of a run instead of just topping up with cold?
     
  5. Thompson1706

    Thompson1706 Part of the furniture

    Registriert seit:
    19 November 2007
    Beiträge:
    2.557
    Zustimmungen:
    1.916
    Geschlecht:
    männlich
    Beruf:
    Retired
    Ort:
    Rhiwabon
    Heritage Railway Volunteer:
    Yes I am an active volunteer
     
  6. Thompson1706

    Thompson1706 Part of the furniture

    Registriert seit:
    19 November 2007
    Beiträge:
    2.557
    Zustimmungen:
    1.916
    Geschlecht:
    männlich
    Beruf:
    Retired
    Ort:
    Rhiwabon
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Reading the Mersey Railway tender specification for the condensing locos it states that the tanks will be required to be as full as possible, but with a large valve under each tank to allow for rapid emptying. This would be done at Rock Ferry or Birkenhead Park. The tanks would then be re-filled with cold water. The single injector would not function once the tank water heated up , the crew then having to use one or two of the crosshead driven feed water pumps.

    Bob.
     
  7. Martin Perry

    Martin Perry Nat Pres stalwart Staff Member Moderator Friend

    Registriert seit:
    15 April 2006
    Beiträge:
    16.553
    Zustimmungen:
    7.905
    Ort:
    1012 / 60158
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    The semicircle section of pipe could well have been some sort of anti-siphoning arrangement.
     
    Wenlock gefällt dies.
  8. johnofwessex

    johnofwessex Resident of Nat Pres

    Registriert seit:
    6 April 2015
    Beiträge:
    9.851
    Zustimmungen:
    8.031
    Geschlecht:
    männlich
    Beruf:
    Thorn in my managers side
    Ort:
    72
    Heritage Railway Volunteer:
    No I do not currently volunteer
    On marine engines in my experience no cylinder lubrication was used with saturated steam. I wasn't aware of any particular issues with oil contamination on Scotch boilers -water tube is quite different.

    The SAR Class 26 (Red Devil) had a feed heater, and about 10% of the exhaust steam was recovered. While it did as far as I am aware have feed pumps rather than injectors, you could deliver cold water from the injectors to the feed heater & then the boiler. Again although pumps were used rather than injectors this would be how its done in marine installations
     
  9. Fred Kerr

    Fred Kerr Resident of Nat Pres Friend

    Registriert seit:
    24 März 2006
    Beiträge:
    8.430
    Zustimmungen:
    5.402
    Geschlecht:
    männlich
    Beruf:
    Freelance photo - journalist
    Ort:
    Southport
  10. Jamessquared

    Jamessquared Nat Pres stalwart

    Registriert seit:
    8 März 2008
    Beiträge:
    28.165
    Zustimmungen:
    66.111
    Ort:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I wonder if it was to stop water from the tanks surging back along the condensing pipes and into the blast pipe under braking, where it would then be ejected over all and sundry next time the regulator was opened?

    Tom
     
  11. Wenlock

    Wenlock Well-Known Member Friend

    Registriert seit:
    26 Oktober 2008
    Beiträge:
    2.139
    Zustimmungen:
    1.400
    Geschlecht:
    männlich
    Beruf:
    Bus Driver
    Ort:
    Loughton Essex
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Surely for the crude condensing systems used, there has to be changeover valve somewhere to send exhaust either up the blast pipe OR into the tanks. In that case no such surge would reach the blast pipe. More likely so that the horizontal pipe didn't fill with water when tanks filled, leaving it clear for the initial blast of exhaust steam to be partially condensed by the action of the water surrounding the horizontal pipe before exiting into the tank.
     
    andrewshimmin gefällt dies.
  12. std tank

    std tank Part of the furniture

    Registriert seit:
    20 September 2005
    Beiträge:
    3.949
    Zustimmungen:
    1.087
    Geschlecht:
    männlich
    Beruf:
    Retired
    Ort:
    Liverpool
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    On the Midland Railway Johnson 3F 0-6-0 tanks fitted with condensing gear, the path of the exhaust is controlled by a flap in the blastpipe. This flap is worked from the cab by a linkage system that enters the smokebox on the LH side.
     
  13. John Hughes

    John Hughes New Member

    Registriert seit:
    5 März 2016
    Beiträge:
    4
    Zustimmungen:
    1
    Geschlecht:
    männlich
    Ort:
    Liverpool
    Heritage Railway Volunteer:
    No I do not currently volunteer
    There are some interesting thoughts here. May I take up the very conspicuous pipes connecting the side tanks with the bunker tank on the 2‑6‑2Ts (and probably hidden behind the frames on the 0‑6‑4Ts)? Would these be to facilitate the rapid discharge of hot water? Presumably the specification called for a discharge outlet on both sides and not from the bunker tank, but I wonder if, in practice, it would have been done from the side nearest to the reception tank for hot water. Incidentally, water was discharged at Central Low Level, but never so far as I know from James Street when that was the Liverpool terminus.
     
  14. Jamessquared

    Jamessquared Nat Pres stalwart

    Registriert seit:
    8 März 2008
    Beiträge:
    28.165
    Zustimmungen:
    66.111
    Ort:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Presumably such a valve might be manual operation though, so prone to the crew forgetting to shut. I know that one of the faults in the condensing gear in the Terriers was that water would surge forward back into the smokebox, to the extent that supposedly some drivers took to the ends of the pipes with a hammer to shut them up once and for all, so presumably it was a genuine problem, at least in some designs.

    Tom
     
  15. banburysaint

    banburysaint Member

    Registriert seit:
    12 Januar 2008
    Beiträge:
    324
    Zustimmungen:
    431
    Its a shame we can't steam Cecil Rakes or The Major to find out the practicality of the arrangement fitted to the locomotives.
     
  16. Thompson1706

    Thompson1706 Part of the furniture

    Registriert seit:
    19 November 2007
    Beiträge:
    2.557
    Zustimmungen:
    1.916
    Geschlecht:
    männlich
    Beruf:
    Retired
    Ort:
    Rhiwabon
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    'The Major' had all of the condensing gear removed when it was sold to the Aussies. The condensing gear on 'Cecil Raikes' is intact.

    Bob.
     
    banburysaint gefällt dies.
  17. Spinner

    Spinner Member

    Registriert seit:
    29 Juli 2006
    Beiträge:
    223
    Zustimmungen:
    239
    Beruf:
    Public Servant
    Ort:
    Australia
    Bob is correct. The only sign of condensing gear on 'The Major' are the circular blanking patches on the smokebox sides. Aside of that, imagination.
     
  18. John Hughes

    John Hughes New Member

    Registriert seit:
    5 März 2016
    Beiträge:
    4
    Zustimmungen:
    1
    Geschlecht:
    männlich
    Ort:
    Liverpool
    Heritage Railway Volunteer:
    No I do not currently volunteer
    To see a condensing loco actually working would certainly answer a lot of questions, but are there no memoirs that cover these points? How about a live-steam model?

    The Mersey Railway had some very steep gradients – up to 1 in 27 – but there would apparently be no exhaust up the chimney on these stretches. Given that most of the running these engines did was in tunnel, would they have used the blower – or would that have defeated the object? Would they have been able to fire the engines inside the tunnel section without using the blower? Given the undesirability of black smoke perhaps firing could only be done outside the tunnels.
     
    banburysaint gefällt dies.
  19. andrewshimmin

    andrewshimmin Well-Known Member

    Registriert seit:
    18 März 2011
    Beiträge:
    1.772
    Zustimmungen:
    2.179
    Heritage Railway Volunteer:
    No I do not currently volunteer
    By all accounts it was rather grim in the tunnel even with the condensing apparatus, hence the relatively early electrification. Several of my forebears were daily commuters in steam and electric days (as was I at one point).
    Would love to see the locos and other large objects in the NMGM collection in a proper display, but the way things are going for regional museums, I fear the worst.
    Andrew (born Birkenhead, Mum from Crosby, Dad from Wallasey, great-grandfather commuted daily from Wallasey Grove Road to James Street).
     
    banburysaint gefällt dies.
  20. John Hughes

    John Hughes New Member

    Registriert seit:
    5 März 2016
    Beiträge:
    4
    Zustimmungen:
    1
    Geschlecht:
    männlich
    Ort:
    Liverpool
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Its a shame we can't steam Cecil Rakes or The Major to find out the practicality of the arrangement fitted to the locomotives.

    I see there's a working N2, but I suppose that is missing some essential bits. Perhaps they could be replaced?
     

Die Seite empfehlen