Boiler test question

Dieses Thema im Forum 'Steam Traction' wurde von dan.lank gestartet, 2 März 2017.

  1. banburysaint

    banburysaint Member

    Registriert seit:
    12 Januar 2008
    Beiträge:
    322
    Zustimmungen:
    414
    Many thanks for the explanation
     
  2. 45045

    45045 New Member

    Registriert seit:
    28 Juli 2009
    Beiträge:
    117
    Zustimmungen:
    49
    This video shows why we use water rather than a gas for pressure tests. It is a high pressure gas line not a low pressure steam locomotive boiler, so the effects are easier to see (test pressure is well over 100 barg on this pipeline)
    Air or service gas tests are very dangerous and you need a large exclusion zone around what you are testing.
     
  3. martin1656

    martin1656 Nat Pres stalwart Friend

    Registriert seit:
    8 Dezember 2014
    Beiträge:
    19.275
    Zustimmungen:
    12.524
    Geschlecht:
    männlich
    Ort:
    St Leonards
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I Have a question that's very relivent, Its to do with riveting, when i have assisted with boiler work, we have always done "hot" riveting on boilers , rather than cold hydraulic, my question is this, does a hot rivet make a better pressure seal? i would think that once the end is turned over, a red hot rivet , if its done fast enough, will also contract as it cools so effecting a tighter seal , where as a cold rivet will only turn over as far as the strength of the steel or copper will allow it and you may possibly damage the plate dishing the area the rivet is in can anyone who has knowledge of this explain?
     
  4. Wenlock

    Wenlock Well-Known Member Friend

    Registriert seit:
    26 Oktober 2008
    Beiträge:
    2.115
    Zustimmungen:
    1.373
    Geschlecht:
    männlich
    Beruf:
    Bus Driver
    Ort:
    Loughton Essex
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    That is my understanding, I have only book knowledge apart from assisting with riveting at BRC. I don't really understand how a cold hydraulic process can exert the same clamping force between the plates as a contracting hot rivet.

    Michael
     
  5. martin1656

    martin1656 Nat Pres stalwart Friend

    Registriert seit:
    8 Dezember 2014
    Beiträge:
    19.275
    Zustimmungen:
    12.524
    Geschlecht:
    männlich
    Ort:
    St Leonards
    Heritage Railway Volunteer:
    No I do not currently volunteer
    plus with a red hot rivet, the pressure needed to turn over the shank will be less, so hopefully less chance of plate deflection i know that rileys used to prefer cold riveting, but i dont know if that was used on boilers, or just on frames etc,
     