If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

Tornado

الموضوع في 'Steam Traction' بواسطة Leander's Shovel, بتاريخ ‏20 اكتوبر 2007.

  1. Martin Perry

    Martin Perry Nat Pres stalwart Staff Member Moderator Friend

    إنضم إلينا في:
    ‏15 إبريل 2006
    المشاركات:
    16,551
    عدد المعجبين:
    7,897
    مكان الإقامة:
    1012 / 60158
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    We manage to make it work in Marine Enginerooms and Drilling Rig environments which are hardly lab conditions.
     
    MarkinDurham و jnc معجبون بهذا.
  2. class8mikado

    class8mikado Part of the furniture

    إنضم إلينا في:
    ‏1 جوان 2009
    المشاركات:
    3,840
    عدد المعجبين:
    1,644
    الوظيفة:
    Print Estimator/ Repository of Useless Informatio.
    مكان الإقامة:
    Bingley W.Yorks.
    Heritage Railway Volunteer:
    No I do not currently volunteer
    The counter argument is that these vehicles ran for decadeswithout oil warning lights, this particular one has run for 100,000 miles without the slightest hint that this might happen and its forebears did likewise. Perhaps when the cause has been ascertained this kind of thing might be considered but implementing such a system makes a rod for backs it becomes an integral part of the locomotive and as such if it isn't working the loco itself could be deemed unfit to run without it. Pressure on other Locomotive managers to install such systems then follows... like air conditioned coaches - maybe that's a good thing/ maybe its not.
     
    MarkinDurham, LesterBrown, staffordian و 1 شخص آخر معجبون بهذا.
  3. 35B

    35B Nat Pres stalwart

    إنضم إلينا في:
    ‏18 جوان 2011
    المشاركات:
    28,739
    عدد المعجبين:
    28,683
    الجنس:
    ذكر
    مكان الإقامة:
    Grantham
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Not to mention that the real challenge is to design a system that doesn't generate false alerts.

    I've no doubt that it's possible - I can't believe that a steam locomotive is that uniquely difficult and hostile an environment to instrument - but suspect the real issue would lie with calibrating the monitoring. That then becomes an issue of time and effort - on what are still very limited resources compared with the other examples given up thread.
     
    staffordian و jnc معجبون بهذا.
  4. mrKnowwun

    mrKnowwun Part of the furniture

    إنضم إلينا في:
    ‏22 اكتوبر 2011
    المشاركات:
    4,366
    عدد المعجبين:
    2,823
    الوظيفة:
    Retired
    مكان الإقامة:
    West Byfleet
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Indeed its not, but you have a ready stable power supply, you don't have that same issues with steam, extreme heat, horizontal driven rain or snow or the same range of differentials in operating environment. A steam loco makes a marine engine room look like a lab environment in comparison.
     
  5. mrKnowwun

    mrKnowwun Part of the furniture

    إنضم إلينا في:
    ‏22 اكتوبر 2011
    المشاركات:
    4,366
    عدد المعجبين:
    2,823
    الوظيفة:
    Retired
    مكان الإقامة:
    West Byfleet
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Gentlemen a number of steam tours get canceled because of the failure of the existing mandatory electronic systems, and they are in comparison simple systems. You seriously want to get more tours cancelled because of the inevitable spurious failures of relatively trivial warning systems?
     
    staffordian, Jerr Grey و MellishR معجبون بهذا.
  6. Andy Williams

    Andy Williams Well-Known Member

    إنضم إلينا في:
    ‏23 إبريل 2010
    المشاركات:
    1,037
    عدد المعجبين:
    1,063
    الوظيفة:
    Design Engineer
    مكان الإقامة:
    Shropshire
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    In this instance it is doubtful whether temperature monitoring would have made any difference. It is perfectlty feasible, in a situation of reduced or no lubrication, for a piston valve to seize in its liner within its normal operational temperature range.
     
    andalfi1, staffordian, jnc و 4 آخرون معجبون بهذا.
  7. mrKnowwun

    mrKnowwun Part of the furniture

    إنضم إلينا في:
    ‏22 اكتوبر 2011
    المشاركات:
    4,366
    عدد المعجبين:
    2,823
    الوظيفة:
    Retired
    مكان الإقامة:
    West Byfleet
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I dispute they are all much more severe in electronic environmental terms than a steam loco.
     
  8. Big Al

    Big Al Nat Pres stalwart Staff Member Moderator

    إنضم إلينا في:
    ‏30 ماي 2009
    المشاركات:
    22,594
    عدد المعجبين:
    22,727
    مكان الإقامة:
    1016
    Heritage Railway Volunteer:
    No I do not currently volunteer
    At last, a piece of information that makes far more sense than almost all of the chunter so far including the notion that maybe technology could have saved the day on Saturday or into the future.

    There is a certain irony in the fact that the Heritage Railway Association saw fit to give the Coiley Locomotive Engineering Award to the A1ST in February this year. It was stated as for 90 mph running but actually had more, I think, to do with the technology that was introduced to try and safeguard high speed operations such as the very sensible temperature monitoring of the middle big end whilst on test.

    But you can't monitor everything. All you can do is have a rigorous and thorough maintenance regime that keeps a check of all the known risk areas. And as it appears, even that may not be sufficient.
     
  9. Johnb

    Johnb Nat Pres stalwart

    إنضم إلينا في:
    ‏3 ديسمبر 2014
    المشاركات:
    15,542
    عدد المعجبين:
    18,404
    الجنس:
    ذكر
    الوظيفة:
    Retired, best job I've ever had
    مكان الإقامة:
    Buckinghamshire
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I agree, quite apart from the extremes of heat vibrations caused by converting reciprocating motion to rotary motion at speed won't be kind to delicate electronics. The cure would probably be worse than the problem. An enforced stop to examine on a busy mainline because of a red light due to a malfunction of the equipment could become a frequent occurrence. The loco has run 100,000 mile with just one major failure which is a pretty good record so no need for any knee jerk reaction
     
    أعجب بهذه المشاركة Jerr Grey
  10. Victor

    Victor Nat Pres stalwart Friend

    إنضم إلينا في:
    ‏20 أوت 2006
    المشاركات:
    14,530
    عدد المعجبين:
    9,199
    الوظيفة:
    Retired
    مكان الإقامة:
    DEWSBURY West Yorkshire
    Deleted, I'd best try keep out of this, IMO that Mr Bunkers statement/email said all that needs to be said until the A1 lads have got to the bottom of it.
     
    أعجب بهذه المشاركة Johnb
  11. Martin Perry

    Martin Perry Nat Pres stalwart Staff Member Moderator Friend

    إنضم إلينا في:
    ‏15 إبريل 2006
    المشاركات:
    16,551
    عدد المعجبين:
    7,897
    مكان الإقامة:
    1012 / 60158
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I must have been to different drilling sites to you then :D
     
  12. MellishR

    MellishR Resident of Nat Pres Friend

    إنضم إلينا في:
    ‏16 إبريل 2009
    المشاركات:
    8,913
    عدد المعجبين:
    5,851
    Nail on head! It is sometimes worthwhile to monitor the temperatures of parts that should normally run cool, notably the inside big end, as was done routinely with the stink bombs and in a more sophisticated way on the 100 mph test run. (But even that can give you false positives. Some railways have trackside hot box detectors, which get excited when a steam loco with a hot ashpan goes past.) Monitoring the temperature of a piston valve head would not only be challenging to implement but, with steam flowing in and out some of the time and being shut off some of the time, you would get a mass of data containing very little useful information.
     
  13. NSWGR 3827

    NSWGR 3827 New Member

    إنضم إلينا في:
    ‏18 يناير 2009
    المشاركات:
    93
    عدد المعجبين:
    40
    الجنس:
    ذكر
    الوظيفة:
    Fitter & Machineist
    مكان الإقامة:
    Down Under
    Having read all the comments and viewed the Video of the Loco at Peterborough, from what I can see I do not believe that the damage had been caused by a seized Valve as the video at Peterborough shows the inside Radius rod to be completely intact. You get a good look at the 2.03 mark in this video https://www.youtube.com/watch?time_continue=4&v=00N0Y2UCuuo If a valve seized I would expect the radius rod to bear the brunt of the forces involved, and end up severely bent or broken. The damaged components in the 4 foot look very similar to a failure that occurred in another country a few years ago, however this was on a Loco with outside valve gear and at a lot less than 90Mph, and the Combination Lever did not end up broken.
     
  14. JJG Koopmans

    JJG Koopmans Member

    إنضم إلينا في:
    ‏12 نوفمبر 2014
    المشاركات:
    382
    عدد المعجبين:
    474
    الجنس:
    ذكر
    Heritage Railway Volunteer:
    No I do not currently volunteer
    As a consequence I don't see why the discussion is about temperature measurement where an oil flow sensor would suffice.
    Kind regards
    Jos
     
    andalfi1, ross, Chris86 و 5 آخرون معجبون بهذا.
  15. gwalkeriow

    gwalkeriow Well-Known Member

    إنضم إلينا في:
    ‏17 أوت 2009
    المشاركات:
    1,710
    عدد المعجبين:
    1,732
    الجنس:
    ذكر
    الوظيفة:
    Retired.
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I remember LMS 5000 at a Severn valley gala back in the late 70s had a valve seize at low speed, the only damage to the valve gear was a broken combination lever.
     
  16. Spamcan81

    Spamcan81 Nat Pres stalwart

    إنضم إلينا في:
    ‏25 أوت 2007
    المشاركات:
    35,836
    عدد المعجبين:
    22,279
    الوظيفة:
    Training moles
    مكان الإقامة:
    The back of beyond
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    This thread reminds of those that appear on pprune after an aircraft crash. All manner of people claiming all manner of expertise chip in with their theories as to what happened, almost all of which turn out to be wrong.
     
    big.stu, jnc, Sheff و 3 آخرون معجبون بهذا.
  17. Richard Roper

    Richard Roper Well-Known Member

    إنضم إلينا في:
    ‏22 ماي 2006
    المشاركات:
    1,310
    عدد المعجبين:
    1,359
    الجنس:
    ذكر
    الوظيفة:
    Librarian
    مكان الإقامة:
    Just up the road from 56E Sowerby Bridge
    Heritage Railway Volunteer:
    No I do not currently volunteer
    According to the A1 Steam.com's archive page
    https://www.a1steam.com/category/history/
    This from the 2003 section
    Cylinders and valves – Ufone machined all six valvechest liners and the front steamchest covers were machined by North View and delivered to the works. Meanwhile A1 Trust volunteers were making good progress producing the cylinder draincocks.

    Richard.
     
  18. GWR4707

    GWR4707 Nat Pres stalwart

    إنضم إلينا في:
    ‏12 ماي 2006
    المشاركات:
    19,232
    عدد المعجبين:
    17,566
    الجنس:
    ذكر
    مكان الإقامة:
    Cumbria
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Wasn't it linings which led to the fall out with WCRC?
     
  19. class8mikado

    class8mikado Part of the furniture

    إنضم إلينا في:
    ‏1 جوان 2009
    المشاركات:
    3,840
    عدد المعجبين:
    1,644
    الوظيفة:
    Print Estimator/ Repository of Useless Informatio.
    مكان الإقامة:
    Bingley W.Yorks.
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Suppose it depends at what point in the cycle the sieze occurs. ie is the motion being crushed or pulled. also break will always occur at the weakest link. which to some extent will vary from design to design or even from loco to loco.
    The fallout with WCRC was a cylinder liner rebore(skim ) using a contractor not on WCRC 'S approved list iirc
     
  20. Steve

    Steve Resident of Nat Pres Friend

    إنضم إلينا في:
    ‏7 اكتوبر 2006
    المشاركات:
    12,734
    عدد المعجبين:
    11,852
    الوظيفة:
    Gentleman of leisure, nowadays
    مكان الإقامة:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    That's a brave thing to say when you are about 10,000 miles further away than those on the spot!
     
    LMS2968, Sawdust و Spamcan81 معجبون بهذا.