    In my old day job, I was certified to be able to work in 3rd rail areas but thankfully I never had to actually be in a 3rd rail area.
    Unlike OHLE which I would be likely to work around day in day out.

    I seem to recall one difference between 3rd rail and Overhead.
    One sticks you to the rail and does not let go while the other throws you off.
    Which one might let you live?

    Maybe it's the perceived risk and the greater degree of separation from the juice.
    You can come in contact with 3rd rail through a trailing bit of clothing or equipment, whereas with OHLE it's up in the air, out of the way and even on a platform you should have more than 9ft clearance. Yes there are traction cables and bonding at ground level but not to the same risk.
     
  2. Jamessquared

    Jamessquared Nat Pres stalwart

    Joined:
    Mar 8, 2008
    Messages:
    26,099
    Likes Received:
    57,414
    Location:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I think there are quite a few Bluebell staff who have their main job working on the big railway who are against even a dummy third rail at HK for exactly that reason.

    Tom
     
  3. 30854

    30854 Resident of Nat Pres

    Joined:
    Mar 8, 2017
    Messages:
    12,172
    Likes Received:
    11,493
    Gender:
    Male
    Occupation:
    Retired
    Location:
    Brighton&Hove
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Many moons ago, I was in the leading carriage of a 4VEP, on the Reading-Waterloo line, which picked up what looked like a bog chain, on the collector equipment, around Sunningdale. Said chain sparked intermittently until the train arrived at Twickenham, where a chap in BR uniform attempted to dislodge it with a broom handle. There followed a very loud 'pop', the chap's bald pate went from skin coloured to blackened and peeling, literally 'in a flash' and there was a very marked and dreadful singing smell. Mercifully, beyond being badly shaken, he was OK as our driver dismounted to lead him onto the platform and assistance. It's not a sight I'd care to see again.
     
  4. Bikermike

    Bikermike Well-Known Member

    Joined:
    Mar 11, 2020
    Messages:
    1,442
    Likes Received:
    1,595
    Gender:
    Male
    Location:
    Thameslink territory
    Heritage Railway Volunteer:
    No I do not currently volunteer
    My favourite is the Northern Line being brought to a halt, by a fancy dress wizard's hat shorting out the traction current
     
  5. Enterprise

    Enterprise Part of the furniture

    Joined:
    Sep 9, 2005
    Messages:
    5,275
    Likes Received:
    3,077
    I would be far more concerned not to get close to 25kV than 750V. Obviously it is best to avoid both!
     
  6. Andy Moody

    Andy Moody Member

    Joined:
    Jul 9, 2007
    Messages:
    496
    Likes Received:
    337
    Occupation:
    Retired
    Location:
    71B ex 71A
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    The Driver should have first obtained an isolation of the traction current, secondly apply a Short circuit bar to the conductor rail and then use a shoe paddle to lift the shoe clear of the conductor rail.
    I take it that we are not going to restart the debate on electrifying East Grinstead to Ardingly again!
     
  7. Dunfanaghy Road

    Dunfanaghy Road Well-Known Member

    Joined:
    Oct 9, 2019
    Messages:
    1,252
    Likes Received:
    1,566
    Gender:
    Male
    Occupation:
    Retired
    Location:
    Alton, Hants
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I have posted in this vein before, I seem to recall, but in simple terms - Read your LRO and TWAO. I'd be surprised if any electrification is permitted.
    Pat
     
    Bluenosejohn, Chris86 and jnc like this.
  8. 30854

    30854 Resident of Nat Pres

    Joined:
    Mar 8, 2017
    Messages:
    12,172
    Likes Received:
    11,493
    Gender:
    Male
    Occupation:
    Retired
    Location:
    Brighton&Hove
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Indeed, though the guy who nearly got fried was identifiably station staff, who's job I'm guessing, it wasn't to attempt to remove the chain in the first place. It was a decidedly sobering sight, which rather underlines why overly close proximity to conductor rails isn't a great idea.

    Down here, Volk's Electric Railway runs on a nominal 110vdc (with unboarded off-centre conductor rail), which voltage drops well below 100 at times. This is lower than was utilised during Magnus Volk's lifetime. Even now, I'd not care to experience a jolt. I can't recall any serious incidents imvolving people over the 35 years I've lived here but have seen mention of two historic fatalities, both young children who'd just come out of the sea (the like's been operating since 1883), although the line's safety record for dogs hasn't been as good, over the years.

    On balance, I suspect not too many would be in favour of a live juice rail on any heritage line.
     
  9. Jamessquared

    Jamessquared Nat Pres stalwart

    Joined:
    Mar 8, 2008
    Messages:
    26,099
    Likes Received:
    57,414
    Location:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I think lots of people seem to want to reopen that debate, but not any of the people who are actually involved in operating the line!

    Tom
     
  10. Big Al

    Big Al Nat Pres stalwart Staff Member Moderator

    Joined:
    May 30, 2009
    Messages:
    21,063
    Likes Received:
    20,773
    Location:
    1016
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Agree. Crazy discussion. I blame whoever started it and I'm not going back to check who it was!
     
  11. Alan Kebby

    Alan Kebby Well-Known Member

    Joined:
    Sep 18, 2019
    Messages:
    1,173
    Likes Received:
    1,223
    Gender:
    Male
    Location:
    Brighton
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I think it’s safe to say that third rail electrification is never going to happen on any heritage line.

    However the developments in battery technology are interesting, as are the Essex group’s plans for the ex IOW class 483s. Hopefully EMUs might be able to operate on heritage lines in future.
     
  12. andrewtoplis

    andrewtoplis Well-Known Member

    Joined:
    Mar 28, 2006
    Messages:
    1,357
    Likes Received:
    816
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Just to close off a few points (if Al will let me)

    Re only having the juice rail live when a train is in section - the 'safe' third rail as used on some French tram systems is an electric rail between the running lines even on street sections shared with pedestrians. This is allowed because the rail is energised in such small sections (and vehicle location is so precise) that the rail is only ever live underneath the centre of the vehicle itself and will not be live anywhere else. The system is popular as it avoids unsightly overhead cables. It is questionable whether the concept could ever be transferred to heritage railway use without very substantial re-engineering. It may be possible to reduce risk substantially by having platform area third rail only live for as short a time as possible, but surely is simpler to just install batteries on the trains themselves.

    Hopefully that is this idea put to bed now
     
  13. jnc

    jnc Well-Known Member

    Joined:
    Apr 3, 2012
    Messages:
    1,511
    Likes Received:
    2,706
    Gender:
    Male
    Location:
    Western Atlantic
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I'm curious to know the physics of what happened there, if you know. (I ask as I'm an electrical engineer, but in low-voltage digital, none in high-voltage stuff.) I assume that somehow a circuit was formed through (or across the surface of) the broom handle, and the poor gentleman's body, to ground? If so, I guess the broom handle wasn't as good an insulator as he assumed!

    Noel
     
    misspentyouth62 likes this.
  14. Chris86

    Chris86 Well-Known Member

    Joined:
    Oct 31, 2011
    Messages:
    1,328
    Likes Received:
    1,315
    Occupation:
    Safety, Technical and Offroad Driver Trainer
    Location:
    South Yorkshore
    Heritage Railway Volunteer:
    No I do not currently volunteer
    H&S advisor hat on.

    Is the third rail necessary- does it pose an unnecessary risk to staff & visitors and could it encourage complacency if is there but not live...

    Answer yes.

    So why on earth would you bother?

    Chris
     
    Bluenosejohn and ghost like this.
  15. goldfish

    goldfish Nat Pres stalwart

    Joined:
    Jan 13, 2009
    Messages:
    14,900
    Likes Received:
    12,241
    Nobody with the ability to actually do it ever would. Although that's what they said about Brexit. ;)

    Simon
     
  16. andrewtoplis

    andrewtoplis Well-Known Member

    Joined:
    Mar 28, 2006
    Messages:
    1,357
    Likes Received:
    816
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I don't believe a short piece of dummy third rail on a heritage line would result in any increase in complacency elsewhere where third rail is in use 'for real'.
     
  17. misspentyouth62

    misspentyouth62 Well-Known Member

    Joined:
    Nov 8, 2017
    Messages:
    1,381
    Likes Received:
    1,737
    Gender:
    Male
    Location:
    34D, now flexible
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I spent time in the local telephone Exchange in the 1970s and the training message was " volts, jolt, mills, kill" meaning that one shouldn't overlook that a relatively low voltage DC source can easily melt a screwdriver, wedding ring or wrist watch for the unfortunate technician should they short a bus-bar - even though the source at the TE was 50v dc.

    On the other hand, a static shock from a nylon carpet or the like would involve many 000s of volts if only at minute current. I seem to recall that the training I received told us that it took only 40-60 mA across your chest to stop your heart!

    600-700 vdc and 25Kv ac are not to be compared in terms of which would kill you worse or fastest!
     
  18. Steve

    Steve Resident of Nat Pres Friend

    Joined:
    Oct 7, 2006
    Messages:
    11,930
    Likes Received:
    10,088
    Occupation:
    Gentleman of leisure, nowadays
    Location:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    An HSE Inspector giving a talk stated that the lowest voltage known to have killed someone was 1½ volts. The person concerned had a pacemaker fitted and it stopped that. How true, I cannot say.
     
  19. Cosmo Bonsor

    Cosmo Bonsor Member

    Joined:
    Dec 10, 2014
    Messages:
    221
    Likes Received:
    500
    Gender:
    Male
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I don't think there will ever be 3rd rail electrification on a heritage railway and also any dummy or replica other than a very temporary installation is a no go as well.
    I had a DC lines PTS when I worked for BR (yes it was quite a while ago) and also held a DC and AC lines PTS for when some choochoo went to London Town for a cheeky film job.
    Our instructor for my recent one said 80% of people survive contact with a 3rd rail, 80% of people die if they touch the OHLE. IIRC the current supplied can be in the 8000 A region in 3rd rail territory. I stand to be corrected. As I said it was a long time ago.
    Running tender first watching the wire get very close to the cab was very unnerving. Some bridges are quite low.
    I had to wind points at Keymer Jn a few times, 319s whizzing past your ear at 90 and not a lot of room at the junction.
    It was always in the rain because that's what made the track circuits fail. I really don't miss all of that.
     
  20. Enterprise

    Enterprise Part of the furniture

    Joined:
    Sep 9, 2005
    Messages:
    5,275
    Likes Received:
    3,077
    The energy transferred is the killer. I've had quite a few jolts from devices such as a Van Der Graaf generator, probably about 120kV but I'm still here as the current was very low. On the other hand I have seen a photo of a fox strolling along the 3rd rail. OK for the fox as the 750V was insufficient to produce a significant current across his dry, hard pads.
     