If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

Bulleid Pacifics - Past or Present

Rasprava u 'Steam Traction' pokrenuta od 34007, 13. Svibanj 2008..

  1. Copper-capped

    Copper-capped Part of the furniture

    Pridružen(a):
    19. Travanj 2017.
    Poruka:
    3,355
    Lajkova:
    4,079
    Spol:
    Muškarac
    Grad:
    Stanthorpe, QLD, Australia
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I like it! Cue the music every time she drifts into the station….
     
    green five and 30854 like this.
  2. DismalChips

    DismalChips Member

    Pridružen(a):
    11. Travanj 2016.
    Poruka:
    682
    Lajkova:
    715
    Grad:
    9A
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Apparently the winner is "Elizabeth II" which is somewhat dull and predictable to my mind, but probably the right choice for the occasion.
     
  3. 30854

    30854 Resident of Nat Pres

    Pridružen(a):
    8. Ožujak 2017.
    Poruka:
    12,172
    Lajkova:
    11,496
    Spol:
    Muškarac
    Interesi:
    Retired
    Grad:
    Brighton&Hove
    Heritage Railway Volunteer:
    No I do not currently volunteer
    What were you expecting, Maximilien Robespierre? ;)
     
  4. Steamage

    Steamage Part of the furniture

    Pridružen(a):
    14. Rujan 2005.
    Poruka:
    4,751
    Lajkova:
    1,126
    Grad:
    Oxford
    I suspect this is the one that will stick ;-)
     
  5. Chris86

    Chris86 Well-Known Member

    Pridružen(a):
    31. Listopad 2011.
    Poruka:
    1,577
    Lajkova:
    1,786
    Interesi:
    Safety, technical and vehicle trainer
    Grad:
    South Yorkshire
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Its only ever going to be be Barney the Dinosaur to me.
     
    Matt37401 and ghost like this.
  6. Eightpot

    Eightpot Resident of Nat Pres Friend

    Pridružen(a):
    10. Kolovoz 2006.
    Poruka:
    8,340
    Lajkova:
    2,506
    Spol:
    Muškarac
    Interesi:
    Engineer Emeritus
    Grad:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    As far as evaporation rates are concerned it should be remembered that the A4 only had a grate area of 41.25 square feet, the 'Duchess' 50, and the MN 48.5 - figures from memory, so stand to be corrected. On this basis, the yet to appear Peppercorn A1 would probably produce results very comparable with the 'Duchess' and MN. Interestingly, BR found during testing at Rugby that removal of the Thermic Syphons fitted to the MN made little or no difference to its steam generation capabilities.
     
  7. Jamessquared

    Jamessquared Nat Pres stalwart

    Pridružen(a):
    8. Ožujak 2008.
    Poruka:
    27,811
    Lajkova:
    64,529
    Grad:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Worth remembering that the purpose of fitting thermic syphons to the Bulleid Pacifics was as a measure to ensure that in low water situations, there would continue to be a flow of water over the firebox crown. They weren’t fitted with the objective of increasing evaporation rate.

    Tom
     
  8. Jamessquared

    Jamessquared Nat Pres stalwart

    Pridružen(a):
    8. Ožujak 2008.
    Poruka:
    27,811
    Lajkova:
    64,529
    Grad:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    On the topic of thermal efficiency: Bulleid was of the view that passengers would notice a train that was delayed (for example due to being short of steam for the job) or didn’t run at all, but wouldn’t care much about a few percent change in coal consumption. In other words, steam raising was prioritised over efficiency. In the same way, from a passenger’s point of view, a loco too big for the job is less of a crime than one struggling to keep to schedule because it is on the limit of its capacity.

    It’s possible to get too hung up on efficiency and ignore more important factors - from a century earlier, you might consider the remarkable claims Beattie made for the thermal efficiency of his locos, while, glossed over, the availability must have been poor by contemporary standards.

    Tom
     
    Last edited: 23. Ožujak 2022.
    Sunnieboy, MellishR, Steve i 2 ostalih se sviđa ovo.
  9. Eightpot

    Eightpot Resident of Nat Pres Friend

    Pridružen(a):
    10. Kolovoz 2006.
    Poruka:
    8,340
    Lajkova:
    2,506
    Spol:
    Muškarac
    Interesi:
    Engineer Emeritus
    Grad:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    As this implies the risk of a collapsed firebox crown sheet, I'm afraid that I can't buy this explanation.
     
  10. Maunsell907

    Maunsell907 Member

    Pridružen(a):
    4. Studeni 2013.
    Poruka:
    915
    Lajkova:
    2,078
    Spol:
    Muškarac
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Bulleid to the Institute of Mechanical Engineers, Dec 1945

    QUOTE “The successful introduction of the Nicholson thermic syphon had provided a reliable means of
    improving the boiler circulation whilst at the same time, giving added security against the overheating
    of the crown plate” END QUOTE

    Taken from an advance copy of the paper.

    Michael Rowe
     
    Last edited: 23. Ožujak 2022.
    Sunnieboy, Steve i Jamessquared se sviđa ovo.
  11. Jamessquared

    Jamessquared Nat Pres stalwart

    Pridružen(a):
    8. Ožujak 2008.
    Poruka:
    27,811
    Lajkova:
    64,529
    Grad:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    See Bulleid’s quote given below by @Maunsell907 - whether you buy it or not, it was the explicit reason stated by Bulleid for fitting syphons.

    Tom
     
    Sunnieboy and Chris86 like this.
  12. Eightpot

    Eightpot Resident of Nat Pres Friend

    Pridružen(a):
    10. Kolovoz 2006.
    Poruka:
    8,340
    Lajkova:
    2,506
    Spol:
    Muškarac
    Interesi:
    Engineer Emeritus
    Grad:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Thermic syphons didn't prevent the boiler explosion of the C & O No. 1642 in 1953.

     
    Last edited: 24. Ožujak 2022.
  13. Copper-capped

    Copper-capped Part of the furniture

    Pridružen(a):
    19. Travanj 2017.
    Poruka:
    3,355
    Lajkova:
    4,079
    Spol:
    Muškarac
    Grad:
    Stanthorpe, QLD, Australia
    Heritage Railway Volunteer:
    No I do not currently volunteer
    An excellent point Tom. I would also imagine that a bigger engine working well within its capabilities is going to wear out far slower than a smaller engine frequently being pushed hard.
     
  14. Big Al

    Big Al Nat Pres stalwart Staff Member Moderator

    Pridružen(a):
    30. Svibanj 2009.
    Poruka:
    22,600
    Lajkova:
    22,734
    Grad:
    1016
    Heritage Railway Volunteer:
    No I do not currently volunteer
    But thermic syphons had nothing to do with why that boiler exploded in the first place. So what are you saying???
     
  15. Allegheny

    Allegheny Member

    Pridružen(a):
    8. Svibanj 2015.
    Poruka:
    637
    Lajkova:
    311
    Spol:
    Muškarac
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Sounds a bit WIBN to me:)
     
    5944 and Jamessquared like this.
  16. Allegheny

    Allegheny Member

    Pridružen(a):
    8. Svibanj 2015.
    Poruka:
    637
    Lajkova:
    311
    Spol:
    Muškarac
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I think this was more of an issue on larger boilers, hence greater usage of thermic syphons in the US.
     
  17. Jamessquared

    Jamessquared Nat Pres stalwart

    Pridružen(a):
    8. Ožujak 2008.
    Poruka:
    27,811
    Lajkova:
    64,529
    Grad:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I refer you to exhibit A - imagine being the poor boiler smith trying to keep that lot in order ready for the morning's service while working overnight in a dimly-lit running shed :)

    0E2A3E0F-38AC-4D54-A5AE-09E0A1AE3954.jpeg 7AA63228-09C6-49C7-BF62-BFC52B711772.jpeg

    Tom
     
  18. Eightpot

    Eightpot Resident of Nat Pres Friend

    Pridružen(a):
    10. Kolovoz 2006.
    Poruka:
    8,340
    Lajkova:
    2,506
    Spol:
    Muškarac
    Interesi:
    Engineer Emeritus
    Grad:
    Aylesbury
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    The way I interpret this is that he is saying that with the water level surrounding the firebox being below that of the crown sheet, that the syphons will still eject water over the higher level of the crown sheet itself and cool it down, thus preventing collapse. This I find difficult to accept. In this situation whether the cause is pump or injector failure, faulty water gauges, mis-handing, etc., the end result is the same .
     
  19. 30854

    30854 Resident of Nat Pres

    Pridružen(a):
    8. Ožujak 2017.
    Poruka:
    12,172
    Lajkova:
    11,496
    Spol:
    Muškarac
    Interesi:
    Retired
    Grad:
    Brighton&Hove
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Isn't all mentioned there the case with or without thermic syphons?
     
  20. Jamessquared

    Jamessquared Nat Pres stalwart

    Pridružen(a):
    8. Ožujak 2008.
    Poruka:
    27,811
    Lajkova:
    64,529
    Grad:
    LBSC 215
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    That is the mechanism, and it is the stated reason that Bulleid fitted them to his pacifics. I've also seen it stated as the reason they were fitted to certain American locomotives.

    You may find it difficult to accept, but the point being made is that that was the reason stated by Bulleid as to why they were used.

    Tom
     
    S.A.C. Martin and Sunnieboy like this.

Podijelite ovu stranicu