If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

Southwold Railway

Discussion in 'Narrow Gauge Railways' started by Bar Side, May 7, 2012.

  1. James Hewett

    James Hewett Member

    Joined:
    Aug 19, 2015
    Messages:
    243
    Likes Received:
    1,037
    Gender:
    Male
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Hi - as far as I know, all CT locos were diesel, including the Hunslet rack locos (we have one whihc worked above ground, an RFS 4WDH - it is now up for sale, in fact may be already sold). Still, if they also had BEs on 900mm, that'd be interesting, as with the wide wheels they are JUST possible to accommodate on three-foot, by adjusting pointwork check rails. James
     
  2. bantamd14

    bantamd14 New Member

    Joined:
    Jan 21, 2017
    Messages:
    150
    Likes Received:
    102
    Gender:
    Male
    Location:
    Stafford
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    James, thanks for putting me straight. I just assumed those working underground would be battery.
     
  3. Steve

    Steve Nat Pres stalwart Friend

    Joined:
    Oct 7, 2006
    Messages:
    13,794
    Likes Received:
    14,855
    Occupation:
    Gentleman of leisure, nowadays
    Location:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Wouldn’t using 900 gauge locos on 3 foot gauge track make them liable to yaw on straight track and moving the check rails potentially create problems if running true 3 foot gauge locos and stock? Check rails have a purpose.
     
  4. James Hewett

    James Hewett Member

    Joined:
    Aug 19, 2015
    Messages:
    243
    Likes Received:
    1,037
    Gender:
    Male
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Yes, it's not absolutely ideal - but needs must, sometimes! The RFS loco we have (900mm gauge) has its wheel back-to-backs set at 841mm, which is only 7mm (and therefore 3.5mm each side) narrower than the Southwold Railway's original 848mm. We have been running this loco together with three-foot-gauge stock on our workshop test track (which intentionally includes a sharpish point and some very sharp curves) for a while - it's a matter of adjusting both wing rail and check rail distances to compromise. However, now we are selling the RFS, we can re-adjust the checks and wings to our wider B to Bs - the Royal Navy wagons we are using have considerably narrower wheels than the original SR stock, so give us less leeway.
    James
     
  5. kscanes

    kscanes Resident of Nat Pres

    Joined:
    Jan 1, 2008
    Messages:
    10,592
    Likes Received:
    5,147
    Not really relevant to the thread but as a point of accuracy, perhaps half of the narrow gauge locos used on the UK side of the Channel Tunnel contract were combined battery electric / ohw electric, including all but two of the twenty rack locos. Only one or two electrics escaped scrapping at the end of the contract. Even if there were any still kicking around I suspect they would have been somewhat over powered and over weight for you; if I recall correctly they started at 170hp or so, and went up to 350hp for the rack locos.
     
    Last edited: Nov 8, 2026
  6. hoffman

    hoffman New Member

    Joined:
    Aug 7, 2016
    Messages:
    55
    Likes Received:
    54
    Gender:
    Male
    Location:
    Suffolk
    Heritage Railway Volunteer:
    No I do not currently volunteer
  7. ross

    ross Well-Known Member

    Joined:
    May 18, 2017
    Messages:
    1,097
    Likes Received:
    2,742
    Gender:
    Male
    Location:
    Titfield
    Heritage Railway Volunteer:
    Yes I am an active volunteer
  8. James Hewett

    James Hewett Member

    Joined:
    Aug 19, 2015
    Messages:
    243
    Likes Received:
    1,037
    Gender:
    Male
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Only a very thick skin - and the ability not to take no for an answer, and to persevere, against all odds (and some say, against all sense...) After all, the answer has been no for almost 100 years, in reaction to the very many attempts to restore the SR.

    NB you should see our PP conditions - they get more onerous every time - and more costly. (Saying that, I well remember that when building the RhE/WHR northwards from Pen-y-Mount Junction, over 20 years ago, 50% of all the spending was on consultants....here it is likely to be at least that percentage) James
     
  9. Bikermike

    Bikermike Well-Known Member

    Joined:
    Mar 11, 2020
    Messages:
    2,316
    Likes Received:
    2,653
    Gender:
    Male
    Location:
    Thameslink territory
    Heritage Railway Volunteer:
    No I do not currently volunteer
    I am deeply curious as to how one "flaunts" planning permission. Do you wave it ostentatiously around the village?
     

Share This Page