If you register, you can do a lot more. And become an active part of our growing community. You'll have access to hidden forums, and enjoy the ability of replying and starting conversations.

lms 2500 to steam?

Rasprava u 'Steam Traction' pokrenuta od Gav106, 1. Travanj 2011..

  1. Spinner

    Spinner Member

    Pridružen(a):
    29. Srpanj 2006.
    Poruka:
    222
    Lajkova:
    238
    Interesi:
    Public Servant
    Grad:
    Australia
    David, In NSW (Australia), we've been doing that for 30 plus years. Water gin + diesel pump = watering steam locomotives on the fly. Since 1970, we've had our traffic locos through piped too, so double ( and triple) headers can get a drink at the same time.
     
  2. meeee

    meeee Member

    Pridružen(a):
    28. Ožujak 2006.
    Poruka:
    886
    Lajkova:
    1,382
    Water lifters were quite common on narrow gauge locos, in particular on the WW1 trench railways. Britomart on the Festiniog has had one fitted, not sure if it has been used on the move though. They work more like ejectors rather than injectors.

    Tim
     
  3. guard_jamie

    guard_jamie Part of the furniture

    Pridružen(a):
    7. Srpanj 2008.
    Poruka:
    2,503
    Lajkova:
    27
    Spol:
    Muškarac
    Interesi:
    Signalman
    Grad:
    Herefordshire
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    If 2500 were to be returned to steam, I imagine that a water hydrant valve would be fitted at the bottom of the tank on one side or the other - it's a modification the usefulness of which outweighs the issue of altering the artefact (the loco) in the first place, and one that the NRM has allowed on other locos in its care. Consequently, a through pipe from a milk wagon, GUC, PMV, CCT or whatever would most likely not require any weird and wonderful means of pumping the water from one to the other - the Panniers, as noted by someone else are a special case due to the height of the tanks.
     
  4. std tank

    std tank Part of the furniture

    Pridružen(a):
    20. Rujan 2005.
    Poruka:
    3,927
    Lajkova:
    1,070
    Spol:
    Muškarac
    Interesi:
    Retired
    Grad:
    Liverpool
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Why not connect directly from a tanker to the bunker waterspace.
     
  5. guard_jamie

    guard_jamie Part of the furniture

    Pridružen(a):
    7. Srpanj 2008.
    Poruka:
    2,503
    Lajkova:
    27
    Spol:
    Muškarac
    Interesi:
    Signalman
    Grad:
    Herefordshire
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    It would make sense to fit the water hydrant valve on the rear to allow for this.
     
  6. pete2hogs

    pete2hogs Member

    Pridružen(a):
    16. Listopad 2007.
    Poruka:
    721
    Lajkova:
    418
    Nevertheless, that's what they did. But it was rather a special situation, as the LT&S duties they were on were entirely self contained - unlike most other duties on the LMS, the locos did not wander away from their home shed, so a slightly more complex loco could presumably be justified on what was probably the most intensive passenger duties on the whole LMS. And with some of the most vocal customers if things went wrong. They didn't cover all duties - the LT&S 4-4-2's carried on until replaced by 2 cyl 2-6-4's (LMS and BR designs) but the 3cyl locos were used as far as possible on the fastest trains.
     
  7. Twirl

    Twirl New Member

    Pridružen(a):
    11. Travanj 2012.
    Poruka:
    4
    Lajkova:
    0
    - Would be great to see this loco to steam agen, lets hope it does happen
     

Podijelite ovu stranicu