    Absolutely. TE is just an impressive and theoretical headline number. Always was, always will be. It simply takes no account of most key design elements.

    The distribution of adhesive weight is just one other factor. That last "-2" on a pacific will always render a 4-6-2 less surefooted than a 4-6-0 of slightly lower nominal TE. That's before you hit considerations such as a decent steam circuit (cough .... "Pendennis Castle"). How many promising looking designs were poor performers because they couldn't effectively use all that steam the poor old fireman shovelled himself to exhaustion to produce?

    As always, t'ain't just what you've got...... it's how you use it that counts!
     
    LMS2968 se sviđa ovo.
  2. johnofwessex

    johnofwessex Resident of Nat Pres

    Pridružen(a):
    6. Travanj 2015.
    Poruka:
    9,792
    Lajkova:
    7,936
    Spol:
    Muškarac
    Interesi:
    Thorn in my managers side
    Grad:
    72
    Heritage Railway Volunteer:
    No I do not currently volunteer
    As was demonstrated by Flying Scotsman on the WSR - I think that Panniers have also demonstrated their superiority over large wheeled express locos on the Paignton & Dartmouth
     
  3. MellishR

    MellishR Resident of Nat Pres Friend

    Pridružen(a):
    16. Travanj 2009.
    Poruka:
    8,998
    Lajkova:
    5,922
    That would need a lot more power than any steam loco that has ever run in Britain. To get that power you would need either a much bigger boiler, which is impossible within the British loading gauge, or to make much more efficient use of the steam, which is possible in principle but would require major improvements in various aspects of design.
     
  4. BrightonBaltic

    BrightonBaltic Member

    Pridružen(a):
    26. Svibanj 2011.
    Poruka:
    724
    Lajkova:
    242
    Well, considering nobody ever got near the maximum steaming capacity of the MN, and a 4-6-4 version could have bigger driving wheels and a bigger firebox, so a slightly longer barrel, bigger thermic syphons and a 70sqft grate, fed by a mechanical stoker... possibly use Caprotti valve gear...
     
  5. LMS2968

    LMS2968 Part of the furniture

    Pridružen(a):
    1. Rujan 2006.
    Poruka:
    3,083
    Lajkova:
    5,393
    Spol:
    Muškarac
    Interesi:
    Lecturer retired: Archivist of Stanier Mogul Fund
    Grad:
    Wigan
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    The maximum output of a MN boiler was, I believe, 41,000lb/ hour. A Stanier 1X boiler produced 41,500lb/hour. That wasn't the maximum the boiler could produce but the maximum the engine could take without slipping.
     
  6. johnofwessex

    johnofwessex Resident of Nat Pres

    Pridružen(a):
    6. Travanj 2015.
    Poruka:
    9,792
    Lajkova:
    7,936
    Spol:
    Muškarac
    Interesi:
    Thorn in my managers side
    Grad:
    72
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Given that David Wardale managed to get 15% thermal efficiency across the entire steaming range with the SAR Class 26 which achieved 4492 IHP/3787 EDHP there seems to be the potential to develop quite a lot of power even within the UK loading gauge
     
    BrightonBaltic se sviđa ovo.
  7. clinker

    clinker Member

    Pridružen(a):
    8. Listopad 2016.
    Poruka:
    615
    Lajkova:
    372
    Spol:
    Muškarac
    Grad:
    romford
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Back to the OP of New Boiler Inspection Rules, I'm guessing that we are looking at a practice run here, for about 30 years insurance companies and similar bodies have hidden behind 'Brussells' 'New European Rulings' 'European Health And Safety' and any other lie that can be attributed to 'Europe'. In the next couple of years that's all got to stop, they can't hide behind, or blame 'Europe' any more, they've managed to get a fair idea of how gullible we, as a movement can be, now they've got to try to push their luck and find something else to hide behind. As a 'Historical' guide, think back to 'Duke of Gloucester''s first restoration.
     
    BrightonBaltic se sviđa ovo.
  8. W.Williams

    W.Williams Well-Known Member

    Pridružen(a):
    20. Prosinac 2015.
    Poruka:
    1,658
    Lajkova:
    1,572
    Interesi:
    Mechanical Engineer
    Grad:
    Aberdeenshire
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    What are you talking about? What relevance does the EU have here? Or are you just taking issue with the HSE act, one of the foundations of modern working practice, that has saved countless lives and made work safer and healthier for eveyone.
     
    johnofwessex se sviđa ovo.
  9. johnofwessex

    johnofwessex Resident of Nat Pres

    Pridružen(a):
    6. Travanj 2015.
    Poruka:
    9,792
    Lajkova:
    7,936
    Spol:
    Muškarac
    Interesi:
    Thorn in my managers side
    Grad:
    72
    Heritage Railway Volunteer:
    No I do not currently volunteer
    And has nothing to do with the EU...........................
     
    andrewshimmin se sviđa ovo.
  10. Steve

    Steve Resident of Nat Pres Friend

    Pridružen(a):
    7. Listopad 2006.
    Poruka:
    12,819
    Lajkova:
    12,017
    Interesi:
    Gentleman of leisure, nowadays
    Grad:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Well this post has totally confused the OP. Care to explain what European legislation is relevant and what guidance is given by DOG?
     
  11. clinker

    clinker Member

    Pridružen(a):
    8. Listopad 2016.
    Poruka:
    615
    Lajkova:
    372
    Spol:
    Muškarac
    Grad:
    romford
    Heritage Railway Volunteer:
    No I do not currently volunteer



    Basically NO EU legislation is relevant, which is the point I'm trying to make, BUT for 30 odd years insurance companies and similar bodies have HIDDEN BEHIND irrelevant and more to the point non existent rulings that can easily be blamed on Europe, suddenly they won't be able to, so have to find something else to hide behind, so as some sort of trial run there's been some sort of 'change' to boiler inspection rulings, so far on here no-ones come up with anything solid as to what these changes are so that is all that I'm suggesting, I've got no problem with existing rulings or the HSE or having boiler inspections, I'm just suggesting that maybe we are being checked out as to what we may be prepared to stand for. Just seeing if, as a movement we are as gullible as they think we could be. WRT Duke of Gloucester, if you're not old enough to remember I'm sure that it is documented somewhere.
     
  12. BrightonBaltic

    BrightonBaltic Member

    Pridružen(a):
    26. Svibanj 2011.
    Poruka:
    724
    Lajkova:
    242
    Duke of Gloucester's restoration was completed five years before I was born... so I'm keen to learn what happened to it!
     
  13. W.Williams

    W.Williams Well-Known Member

    Pridružen(a):
    20. Prosinac 2015.
    Poruka:
    1,658
    Lajkova:
    1,572
    Interesi:
    Mechanical Engineer
    Grad:
    Aberdeenshire
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Wait, so, you are saying this is empty speculation on your part? That there is some fabricated reason, that may be distantly related to the EU?

    Could it not be that an Engineer, or group of Engineers have perhaps taken this decision out of evidence and reason, and not some baseless political innuendo?
     
  14. Steve

    Steve Resident of Nat Pres Friend

    Pridružen(a):
    7. Listopad 2006.
    Poruka:
    12,819
    Lajkova:
    12,017
    Interesi:
    Gentleman of leisure, nowadays
    Grad:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Duke of Gloucester was completed five years after I was born and I'm still keen to learn what happened to it!
     
    std tank se sviđa ovo.
  15. Steve

    Steve Resident of Nat Pres Friend

    Pridružen(a):
    7. Listopad 2006.
    Poruka:
    12,819
    Lajkova:
    12,017
    Interesi:
    Gentleman of leisure, nowadays
    Grad:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    We have some very knowledgeable people on here yet no one has come up with what these new rules are or even might be. I'm starting to suspect that a mistake has been made but who by and what it is, I don't know.
     
    std tank and W.Williams like this.
  16. 30854

    30854 Resident of Nat Pres

    Pridružen(a):
    8. Ožujak 2017.
    Poruka:
    12,172
    Lajkova:
    11,496
    Spol:
    Muškarac
    Interesi:
    Retired
    Grad:
    Brighton&Hove
    Heritage Railway Volunteer:
    No I do not currently volunteer
    Could we please avoid any descent into less than enlightening presumption and suppositon regarding the origin of relevant legislation?

    Whatever the future holds, safety legislation will exist and we have a thread infinitely better suited to unproductive exposition of personal viewpoints relating to the pros and cons of the ongoing wider political debate.
     
  17. estwdjhn

    estwdjhn Member

    Pridružen(a):
    24. Siječanj 2013.
    Poruka:
    343
    Lajkova:
    696
    Interesi:
    Boilermaker
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Actually, the relevant bit of legislation is the Pressure Equipment Directive, which most definitely is EU legislation.
    Most of the practical outworking has just been to point people back to all the usual standards (stuff like BS931 etc), however there are some special extra bits of EU silliness that got thrown in along the way (e.g. new boilers much now be supplied with instructions for the end user).

    That said, as far as I know nothing in this has changed even slightly.

    If I was a gambling man (I've no knowledge of this particular situation), I'd hazard a guess that what has happened here is a difference of option about something between the boiler inspector, the insurance company or the vehicle acceptance body (VAB). I've been in the middle of this particular situation once(the boiler inspector said everything was fine, the VAB man had other ideas), and getting a resolution can be interesting to say the least.
     
    Steve and 35B like this.
  18. Steve

    Steve Resident of Nat Pres Friend

    Pridružen(a):
    7. Listopad 2006.
    Poruka:
    12,819
    Lajkova:
    12,017
    Interesi:
    Gentleman of leisure, nowadays
    Grad:
    Near Leeds
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    Your last para would be most likely except that we are not talking about a loco destined to go main line. Or is it!? Has the overhaul been done with Wareham in mind? As you say, different rules can apply.
    With regard to the comments about EU legislation I'd discounted the PER/PED as we were not talking about a new boiler and the PSSR is firmly rooted in UK legislation with no hint of EU legislation being involved.
     
    burmister se sviđa ovo.
  19. std tank

    std tank Part of the furniture

    Pridružen(a):
    20. Rujan 2005.
    Poruka:
    3,941
    Lajkova:
    1,076
    Spol:
    Muškarac
    Interesi:
    Retired
    Grad:
    Liverpool
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    I note that the procedures for testing a steam locomotive boiler in the 1950 edition of the Red Book and the ORR's RSP6 The Management of Steam Locomotive Boilers (2007) are pretty well the same.
    Where does Europe come into the equation?
     
  20. Phil-d259

    Phil-d259 Member

    Pridružen(a):
    2. Travanj 2015.
    Poruka:
    703
    Lajkova:
    736
    Spol:
    Muškarac
    Heritage Railway Volunteer:
    Yes I am an active volunteer
    And what is so silly about providing instructions for the end user on how to operate what is potentially a dangerous bit of kit properly. Would you be happy having a new central heating boiler installed but nothing to refer to to tell you how it worked?

    Granted a new steam locomotive boiler is extremely unlikely to end up in the hands of an organisation that doesn't know how to operate it, but in legislative terms far better to go for a keep it simple / blanket approch rather then trying to list all possible situations where instructions are necessary - because you can bet that someone, somewhere would find a loophole they could exploit.
     